Heat pumps · Compare

DeWarmte Pomp MP vs M-TEC AHPC412

SCOP (35 °C): DeWarmte Pomp MP 5.05, M-TEC AHPC412 4.74. The DeWarmte Pomp MP is better on 10 of 14 comparable points.

Who wins where

  • DeWarmte Pomp MP
  • M-TEC AHPC412
PerformanceEfficiencyNoiseRefrigerantConnectivity & smartGrants & market
Performance: DeWarmte Pomp MP 42, M-TEC AHPC412 45; Efficiency: DeWarmte Pomp MP 75, M-TEC AHPC412 44; Noise: DeWarmte Pomp MP 59, M-TEC AHPC412 26; Refrigerant: DeWarmte Pomp MP 80, M-TEC AHPC412 79; Connectivity & smart: DeWarmte Pomp MP 50, M-TEC AHPC412 50; Grants & market: DeWarmte Pomp MP 42, M-TEC AHPC412 31

Biggest differences

FactPomp MPAHPC412
COP A7/W356.444.53
COP A2/W355.033.75
ISDE grant (NL)3,250 €2,825 €
Rated output 55 °C8.76 kW9.93 kW
Outdoor unit sound power53 dB(A)60 dB(A)
SCOP (35 °C)5.054.74
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications DeWarmtePomp MP M-TECAHPC412
Grants & market
SEAI Heat Pump System Grant €14,500€14,500
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Rated output 35 °C 9.91 kW ✓ 1 9.87 kW 1
Rated output 55 °C 8.76 kW 1 9.93 kW ✓ 1
Efficiency
SCOP (35 °C) 5.05 ✓ 1 4.74 1
SCOP (55 °C) 3.83 ✓ 1 3.7 1
Seasonal efficiency ηs 35 °C 199 % ✓ 1 186.8 % 1
Seasonal efficiency ηs 55 °C 150 % ✓ 1 145 % 1
COP A7/W35 6.44 ✓ 1 4.53 1
COP A2/W35 5.03 ✓ 1 3.75 1
COP A-7/W35 3.17 1 3.28 ✓ 1
Noise
Outdoor unit sound power 53 dB(A) ✓ 1 60 dB(A) 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant GWP 3 2 3 2
Refrigerant charge 1 kg ✓ 1 1.05 kg 1
Electrical
Max. power input 3.6 kW 1 7.1 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1
Grants & market
ISDE grant (NL) 3,250 € ✓ 2 2,825 € 2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026