Heat pumps · UK

ait-deutschlandalpha innotec SWCV 62H1

ait-deutschland alpha innotec SWCV 62H1
Image: ait-deutschlandrequest removal

The ait-deutschland alpha innotec SWCV 62H1 is a heat pump with SCOP (35 °C) 5.18 and refrigerant R407C.1,2

Key figures

SCOP (35 °C)
5.182

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Refrigerant
R407C2
Official source
Type (source)
Ground source2
Official source
Rated output 35 °C
5.5kW2
Official source
Rated output 55 °C
5.5kW2
Official source
UK

Rules in the UK

Boiler Upgrade Scheme

Check conditions

£7,500 – £9,0003Fixed grant (England & Wales)

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.4,5

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 5.5 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 3.95. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type (source) Ground source2
Compressors 11
Capacity control drehzahlregelung1
Performance
Rated output 35 °C 5.5 kW2
Rated output 55 °C 5.5 kW2
Efficiency
SCOP (35 °C) 5.182
SCOP (55 °C) 3.952
Seasonal efficiency ηs 35 °C 199 %2
Seasonal efficiency ηs 55 °C 150 %2
Energy label 35 °C A, , , 2
Energy label 55 °C A, , , 2
Noise
Indoor unit sound power 44 dB(A)2
Refrigerant
Refrigerant R407C2
Refrigerant GWP 1,7742
Refrigerant charge 1.16 kg2
Electrical
Max. power input 0.68 kW1
Connectivity & smart
SG Ready Yes1

Variants

This model is registered in 12 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • alpha innotec SWCV 62H1
  • NOVELAN SICV 6.2(H)(K)3
  • NOVELAN WSV 6.2(H)(K)3M
  • SICV 6.2 (H3 / K3) — Indoor unit sound power: 43 dB(A)
  • SWCV 62 (H3 / K3) — Indoor unit sound power: 43 dB(A)
  • WSV 6.2 (H3M / K3M) — Indoor unit sound power: 43 dB(A)
  • WZSV 62 (H3M / K3M) — Indoor unit sound power: 43 dB(A)
  • alpha innotec PWZSV 62H1S
  • alpha innotec PWZSV 62H2S
  • alpha innotec PWZSV 62H3S
  • alpha innotec SWCV 62(H)(K)3
  • alpha innotec WZSV 62(H)(K)3M

Manufacturer documentation

External links to ait-deutschland's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Frequently asked questions

What is the SCOP (35 °C) of the ait-deutschland alpha innotec SWCV 62H1?

The SCOP (35 °C) of the ait-deutschland alpha innotec SWCV 62H1 is 5.18.1,2

Which refrigerant does the ait-deutschland alpha innotec SWCV 62H1 use?

The refrigerant of the ait-deutschland alpha innotec SWCV 62H1 is R407C.1,2

How much Boiler Upgrade Scheme grant can you get for the ait-deutschland alpha innotec SWCV 62H1?

£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 29 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  4. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026