alpha innotec WZSV 63H1/3M (10082241)
The alpha innotec WZSV 63H1/3M (10082241) is a heat pump with SCOP (35 °C) 5.03, refrigerant R290 (PROPAAN) and max. flow temperature 75 °C.1,2,3
Key figures
Rules in the UK
Boiler Upgrade Scheme
Check conditions£7,500 – £9,0004Fixed grant (England & Wales)
Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.5,6
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
- Rated output 6 kW; the scheme covers systems up to 45 kW.
- SCOP at 55 °C: 3.83. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Technical specifications
| General | |
|---|---|
| Type (source) | Ground source1 |
| Performance | |
| Rated output 35 °C | 6 kW2 |
| Rated output 55 °C | 5 kW2 |
| Max. flow temperature | 75 °C3 |
| Efficiency | |
| SCOP (35 °C) | 5.032 |
| SCOP (55 °C) | 3.832 |
| Seasonal efficiency ηs 35 °C | 198 %2 |
| Seasonal efficiency ηs 55 °C | 150 %2 |
| Energy label 35 °C | A+++2 |
| Energy label 55 °C | A+++2 |
| Noise | |
| Indoor unit sound power | 40 dB(A)2 |
| Refrigerant | |
| Refrigerant | R290 (PROPAAN)1 |
| Refrigerant GWP | 31 |
| Grants & market | |
| ISDE grant (NL) | 4,425 €1 |
How it ranks
SCOP (35 °C): better than 60% of comparable models in our database (Heat pumps · Ground source · 6–8 kW; n = 38).
Rank 16 of 39
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Variants
This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:
- WZSV 63H1/3M (10082241)
- WZSV 63K1/3M (10082341)
Manufacturer documentation
External links to alpha innotec's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from alpha innotec
- alpha innotec SW 42H1 SCOP (35 °C): 4.81
- alpha innotec SWCV 62H1 SCOP (35 °C): 5.18
- alpha innotec SW 62H1 SCOP (35 °C): 5.01
- alpha innotec SW 82H1 SCOP (35 °C): 5.09
- alpha innotec SWCV 122H1 (1~230V) SCOP (35 °C): 5.25
- alpha innotec SW 102H1 SCOP (35 °C): 5.09
Guides on heat pumps
- SCOP, COP and ηs: what a heat pump’s efficiency figures mean
- Hybrid or full heat pump? The main types compared
- Heat pump noise: MCS 020(a), permitted development and where to put the unit
- Sizing a heat pump: heat loss, flow temperature and rated output
- Heat pump refrigerants: R290, R32 and R410A compared
How we collect and check this data →
Frequently asked questions
What is the SCOP (35 °C) of the alpha innotec WZSV 63H1/3M (10082241)?
The SCOP (35 °C) of the alpha innotec WZSV 63H1/3M (10082241) is 5.03.1,2,3
Which refrigerant does the alpha innotec WZSV 63H1/3M (10082241) use?
The refrigerant of the alpha innotec WZSV 63H1/3M (10082241) is R290 (PROPAAN).1,2,3
What is the max. flow temperature of the alpha innotec WZSV 63H1/3M (10082241)?
The max. flow temperature of the alpha innotec WZSV 63H1/3M (10082241) is 75 °C.1,2,3
How much Boiler Upgrade Scheme grant can you get for the alpha innotec WZSV 63H1/3M (10082241)?
£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2,3
Sources
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 27 Sept 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
- Manufacturer data · accessed 8 Nov 2026
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
- Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026