Heat pumps · IE

alpha innotec SWCV 62H1

alpha innotec SWCV 62H1
Image: ait-deutschlandrequest removal

The alpha innotec SWCV 62H1 is a heat pump with SCOP (35 °C) 5.18 and refrigerant R407C.1,2

Key figures

SCOP (35 °C)
5.182

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Refrigerant
R407C2
Official source
Type (source)
Ground source2
Official source
Rated output 35 °C
5.5kW2
Official source
Rated output 55 °C
5.5kW2
Official source
IE

Rules in Ireland

SEAI Heat Pump System Grant

Check conditions

€14,5003Maximum for a house, incl. €2,000 boiler scrappage

Up to €14,500 for a house (€11,500 for an apartment), including a €2,000 boiler scrappage grant when an oil, gas, solid-fuel or storage-heater system is removed. Homes built before 2007 need a technical assessment (€200 grant) unless the BER shows a Heat Loss Indicator of 2.3 or less. Installation is charged at 9% VAT.4

  • The heat pump must be listed on SEAI's Home Appliance Register of Performance (HARP) and installed by an SEAI-registered contractor.
  • Home built and occupied before 2021, with an MPRN; grant approval before any work starts and a BER assessment afterwards.

Heat pumps: grants and rules in Ireland →

Technical specifications

General
Type (source)Ground source2
Compressors11
Capacity controldrehzahlregelung1
Performance
Rated output 35 °C5.5 kW2
Rated output 55 °C5.5 kW2
Efficiency
SCOP (35 °C)5.182
SCOP (55 °C)3.952
Seasonal efficiency ηs 35 °C199 %2
Seasonal efficiency ηs 55 °C150 %2
Energy label 35 °CA+++2
Energy label 55 °CA+++2
Noise
Indoor unit sound power44 dB(A)2
Refrigerant
RefrigerantR407C2
Refrigerant GWP1,7742
Refrigerant charge1.16 kg2
Electrical
Max. power input0.68 kW1
Connectivity & smart
SG ReadyYes1

Variants

This model is registered in 12 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • SWCV 62H1
  • Novelan SICV 6.2(H)(K)3
  • Novelan WSV 6.2(H)(K)3M
  • SICV 6.2 (H3 / K3) — Indoor unit sound power: 43 dB(A)
  • SWCV 62 (H3 / K3) — Indoor unit sound power: 43 dB(A)
  • WSV 6.2 (H3M / K3M) — Indoor unit sound power: 43 dB(A)
  • WZSV 62 (H3M / K3M) — Indoor unit sound power: 43 dB(A)
  • PWZSV 62H1S
  • PWZSV 62H2S
  • PWZSV 62H3S
  • SWCV 62(H)(K)3
  • WZSV 62(H)(K)3M

Manufacturer documentation

External links to alpha innotec's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Similar models

Other brands, same type and a comparable size.

More from alpha innotec

All alpha innotec models (8) →

How we collect and check this data →

Frequently asked questions

What is the SCOP (35 °C) of the alpha innotec SWCV 62H1?

The SCOP (35 °C) of the alpha innotec SWCV 62H1 is 5.18.1,2

Which refrigerant does the alpha innotec SWCV 62H1 use?

The refrigerant of the alpha innotec SWCV 62H1 is R407C.1,2

How much SEAI grant can you get for the alpha innotec SWCV 62H1?

Up to €14,500 with the SEAI Heat Pump System Grant, including €2,000 boiler scrappage when an oil, gas, solid-fuel or storage-heater system is removed (€11,500 for an apartment). The home must be built and occupied before 2021, the heat pump must be on SEAI's HARP register and you need grant approval before work starts.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 18 Oct 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump System Grants — SEAI · accessed 4 Oct 2026
  4. Heat pump heating system (VAT) — Revenue · accessed 4 Oct 2026