Heat pumps · Compare

Samsung AE125DXEDGG/EU+AE160DNZSPG/EU vs Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001

SCOP (35 °C): Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 4.73, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 4.53. The Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 is better on 7 of 15 comparable points.

Who wins where

  • Samsung AE125DXEDGG/EU+AE160DNZSPG/EU
  • Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 69, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 59; Efficiency: Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 37, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 45; Noise: Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 28, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 58; Refrigerant: Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 40, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 55; Connectivity & smart: Samsung AE125DXEDGG/EU+AE160DNZSPG/EU 50, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 50

Biggest differences

FactAE125DXEDGG/EU+AE160DNZSPG/EUIDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
Refrigerant GWP6753
Heating capacity (A7/W35)12.5 kW8.1 kW
COP A7/W354.836.1
Outdoor unit sound power61 dB(A)54 dB(A)
Indoor unit sound power44 dB(A)40 dB(A)
Refrigerant charge1.84 kg2 kg
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications SamsungAE125DXEDGG/EU+AE160DNZSPG/EU ViessmannIDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
Grants & market
Boiler Upgrade Scheme £7,500 – £9,000£7,500 – £9,000
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) 12.5 kW ✓ 2 8.1 kW 3
Rated output 35 °C 12.5 kW ✓ 1 12.42 kW 1
Rated output 55 °C 12.1 kW 1 12.1 kW 1
Min. outdoor temperature – -20 °C 3
Efficiency
SCOP (35 °C) 4.73 ✓ 1 4.53 1
SCOP (55 °C) 3.45 1 3.6 ✓ 1
Seasonal efficiency ηs 35 °C 186 % ✓ 1 178 % 1
Seasonal efficiency ηs 55 °C 135 % 1 141 % ✓ 1
Energy label 35 °C A, , , 2 A, , , 3
Energy label 55 °C A, , 2 A, , 3
COP A7/W35 4.83 1 6.1 ✓ 1
COP A2/W35 4.46 ✓ 1 4.3 1
COP A-7/W35 2.8 1 3 ✓ 1
Noise
Outdoor unit sound power 61 dB(A) 1 54 dB(A) ✓ 1
Indoor unit sound power 44 dB(A) 1 40 dB(A) ✓ 1
Refrigerant
Refrigerant R32 1 R290 1
Refrigerant GWP 675 2 3 ✓ 3
Refrigerant charge 1.84 kg ✓ 1 2 kg 1
Electrical
Max. power input 6.95 kW 1 1.65 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026