Heat pumps · Compare

Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) vs Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E)

SCOP (35 °C): Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 4.77, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 5.01. The Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) is better on 7 of 14 comparable points.

Who wins where

  • Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E)
  • Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E)
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 48, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 48; Efficiency: Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 46, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 58; Noise: Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 93, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 82; Refrigerant: Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 53, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 64; Connectivity & smart: Bosch Compress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) 50, Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) 50

Biggest differences

FactCompress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E)Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E)
SEER (cooling)2.74.46
COP A-7/W352.473.19
COP A2/W354.843.82
Refrigerant charge1.6 kg1.37 kg
Outdoor unit sound power42 dB(A)49 dB(A)
Indoor unit sound power31 dB(A)34 dB(A)
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications BoschCompress CS5800iAW 10 ORE-T (AW 10 OR-T + CS5800iAW 12 E) BuderusLogaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E)
Grants & market
Boiler Upgrade Scheme £7,500 – £9,000£7,500 – £9,000
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Rated output 35 °C 10 kW 1 10 kW 1
Rated output 55 °C 10 kW 1 10 kW 1
Efficiency
SCOP (35 °C) 4.77 1 5.01 ✓ 1
SCOP (55 °C) 3.62 1 3.93 ✓ 1
Seasonal efficiency ηs 35 °C 188 % 1 197 % ✓ 1
Seasonal efficiency ηs 55 °C 142 % 1 154 % ✓ 1
COP A7/W35 4.84 ✓ 1 4.73 1
COP A2/W35 4.84 ✓ 1 3.82 1
COP A-7/W35 2.47 1 3.19 ✓ 1
SEER (cooling) 2.7 1 4.46 ✓ 1
Noise
Outdoor unit sound power 42 dB(A) ✓ 1 49 dB(A) 1
Indoor unit sound power 31 dB(A) ✓ 1 34 dB(A) 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant charge 1.6 kg 1 1.37 kg ✓ 1
Electrical
Max. power input 7.4 kW 1 4.7 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026