Heat pumps · UK

Rotenso AQM120X3

Rotenso AQM120X3
Image: Rotensorequest removal

The Rotenso AQM120X3 is an air-to-water heat pump with a SCOP of 4.81 (35 °C) and a sound power level of 65 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 10.0 m; against a wall 14.2 m.1,2

Key figures

SCOP (35 °C)
4.812

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
12.1kW2
Official source
Outdoor unit sound power
65dB(A)2
Official source
Refrigerant
R322
Official source
Type (source)
Air-to-water2
Official source
UK

Rules in the UK

Minimum distance to your neighbour

MCS 020(a) (England, permitted development since 29 May 2025)3 · 1 m in front of the centre of a neighbour’s habitable-room door or window

Permitted development (MCS 020(a))≤ 37 dB(A) · LAeq,5min
Free-standing10 m
Against wall14.2 m
In corner20 m

Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.

Boiler Upgrade Scheme

Check conditions

£7,500 – £9,0004Fixed grant (England & Wales)

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.5,6

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 12 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 3.45. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type (source)Air-to-water2
Performance
Heating capacity (A7/W35)12.1 kW2
Rated output 35 °C12 kW2
Rated output 55 °C11.58 kW2
Min. outdoor temperature-22 °C2
Efficiency
SCOP (35 °C)4.812
SCOP (55 °C)3.452
Seasonal efficiency ηs 35 °C189 %2
Seasonal efficiency ηs 55 °C135 %2
Energy label 35 °CA+++2
Energy label 55 °CA++2
COP A7/W354.952
Noise
Outdoor unit sound power65 dB(A)2
Refrigerant
RefrigerantR322
Refrigerant GWP6752
Refrigerant charge1.84 kg2
Grants & market
ISDE grant (NL)3,700 €1

How it ranks

SCOP (35 °C): better than 55% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).

Rank 138 of 310

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Manufacturer documentation

External links to Rotenso's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Rotenso

All Rotenso models (15) →

Guides on heat pumps

How we collect and check this data →

Frequently asked questions

Can I install the Rotenso AQM120X3 without planning permission?

Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 65 dB(A) that indicatively means 10.0 m free-standing, 14.2 m against a wall or 20.0 m in a corner. Your MCS installer must confirm this.1,2

How much Boiler Upgrade Scheme grant can you get for the Rotenso AQM120X3?

£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2

Which refrigerant does the Rotenso AQM120X3 use?

The Rotenso AQM120X3 uses R32.1,2

Sources

  1. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. MCS 020(a) (England, permitted development since 29 May 2025)
  4. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  5. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
  6. Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026