M-TECVHPA27
The M-TEC VHPA27 is a heat pump with SCOP (35 °C) 5.51 and refrigerant R290.
Key figures
- SCOP (35 °C)
- 5.51
Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.
- Refrigerant
- R290Official source
- Rated output 35 °C
- 7.65kWOfficial source
- Rated output 55 °C
- 6.71kWOfficial source
- Max. power input
- 2.37kWOfficial source
UK
Rules in the UK
These rules are still being verified.
Boiler Upgrade Scheme
UnknownFixed grant towards installation; check current amount with Ofgem. Ofgem
Technical specifications
| General | ||
|---|---|---|
| Type | Ground source | BAFA |
| Compressors | 1 | BAFA |
| Capacity control | Inverter | BAFA |
| Performance | ||
| Rated output 35 °C | 7.65 kW | BAFA |
| Rated output 55 °C | 6.71 kW | BAFA |
| Efficiency | ||
| SCOP (35 °C) | 5.51 | BAFA |
| SCOP (55 °C) | 4.01 | BAFA |
| Seasonal efficiency ηs 35 °C | 212.6 % | BAFA |
| Seasonal efficiency ηs 55 °C | 157.4 % | BAFA |
| COP A7/W35 | 6.35 | BAFA |
| COP A-7/W35 | 4.36 | BAFA |
| Noise | ||
| Indoor unit sound power | 39.8 dB(A) | BAFA |
| Refrigerant | ||
| Refrigerant | R290 | BAFA |
| Refrigerant GWP | 3 | RVO ISDE list |
| Refrigerant charge | 0.15 kg | BAFA |
| Electrical | ||
| Max. power input | 2.37 kW | BAFA |
| Connectivity & smart | ||
| SG Ready | Yes | BAFA |
| Grants & market | ||
| ISDE grant (NL) | 4,425 € | RVO ISDE list |
Frequently asked questions
What is the SCOP (35 °C) of the M-TEC VHPA27?
The SCOP (35 °C) of the M-TEC VHPA27 is 5.51.
Which refrigerant does the M-TEC VHPA27 use?
The refrigerant of the M-TEC VHPA27 is R290.