Chint PVSTAR Energy SolutionPVS-HP 012TC3
The Chint PVSTAR Energy Solution PVS-HP 012TC3 is an air-to-water heat pump with a SCOP of 4.74 (35 °C) and a sound power level of 60 dB(A). Under permitted development the limit is 42 dB(A) measured 1 m from the nearest neighbouring habitable-room window. Free-standing, the indicative minimum distance is 3.2 m; against a wall 4.5 m.
Key figures
- SCOP (35 °C)
- 4.74
Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.
- Outdoor unit sound power
- 60dB(A)Official source
- Refrigerant
- R290Official source
- Rated output 35 °C
- 9.87kWOfficial source
- Rated output 55 °C
- 9.93kWOfficial source
Rules in the UK
These rules are still being verified.
Minimum distance to your neighbour
Permitted development rights + MCS 020 planning standard · 1 m from the nearest neighbouring habitable-room window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment. Source
Boiler Upgrade Scheme
UnknownFixed grant towards installation; check current amount with Ofgem. Ofgem
Technical specifications
| General | ||
|---|---|---|
| Type | Air-to-water | BAFA |
| Compressors | 1 | BAFA |
| Capacity control | drehzahlregelung | BAFA |
| Performance | ||
| Rated output 35 °C | 9.87 kW | BAFA |
| Rated output 55 °C | 9.93 kW | BAFA |
| Efficiency | ||
| SCOP (35 °C) | 4.74 | BAFA |
| SCOP (55 °C) | 3.7 | BAFA |
| Seasonal efficiency ηs 35 °C | 186.8 % | BAFA |
| Seasonal efficiency ηs 55 °C | 145 % | BAFA |
| COP A7/W35 | 4.53 | BAFA |
| COP A2/W35 | 4.6 | BAFA |
| COP A-7/W35 | 3.18 | BAFA |
| Noise | ||
| Outdoor unit sound power | 60 dB(A) | BAFA |
| Indoor unit sound power | 46 dB(A) | BAFA |
| Refrigerant | ||
| Refrigerant | R290 | BAFA |
| Refrigerant charge | 1.05 kg | BAFA |
| Electrical | ||
| Max. power input | 5.85 kW | BAFA |
| Connectivity & smart | ||
| SG Ready | Yes | BAFA |
Frequently asked questions
Can I install the Chint PVSTAR Energy Solution PVS-HP 012TC3 without planning permission?
Under Permitted development rights + MCS 020 planning standard the unit must not exceed 42 dB(A) 1 m from the nearest neighbouring habitable-room window. With a sound power of 60 dB(A) that indicatively means 3.2 m free-standing, 4.5 m against a wall or 6.3 m in a corner. Your MCS installer must confirm this.
Which refrigerant does the Chint PVSTAR Energy Solution PVS-HP 012TC3 use?
The Chint PVSTAR Energy Solution PVS-HP 012TC3 uses R290.