Heat pumps · Compare

Chint PVS-HP 012TC3 vs Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001

SCOP (35 °C): Chint PVS-HP 012TC3 4.74, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 4.83. Both models win equally often (5 of 14 points).

Who wins where

  • Chint PVS-HP 012TC3
  • Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Chint PVS-HP 012TC3 54, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 42; Efficiency: Chint PVS-HP 012TC3 48, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 61; Noise: Chint PVS-HP 012TC3 26, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 61; Refrigerant: Chint PVS-HP 012TC3 79, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 55; Connectivity & smart: Chint PVS-HP 012TC3 50, Viessmann IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001 50

Biggest differences

FactPVS-HP 012TC3IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001
Refrigerant charge1.05 kg2 kg
Heating capacity (A7/W35)12.09 kW7.3 kW
COP A7/W354.536
Indoor unit sound power46 dB(A)40 dB(A)
Outdoor unit sound power60 dB(A)53 dB(A)
Rated output 55 °C9.93 kW9.37 kW
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications ChintPVS-HP 012TC3 ViessmannIDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001
Grants & market
Boiler Upgrade Scheme £7,500 – £9,000£7,500 – £9,000
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) 12.09 kW ✓ 2 7.3 kW 3
Rated output 35 °C 9.87 kW ✓ 1 9.8 kW 1
Rated output 55 °C 9.93 kW ✓ 1 9.37 kW 1
Min. outdoor temperature – -20 °C 3
Efficiency
SCOP (35 °C) 4.74 1 4.83 ✓ 1
SCOP (55 °C) 3.7 1 3.7 1
Seasonal efficiency ηs 35 °C 186.8 % 1 190 % ✓ 1
Seasonal efficiency ηs 55 °C 145 % 1 145 % 1
Energy label 35 °C A, , , 2 A, , , 3
Energy label 55 °C A, , 2 A, , 3
COP A7/W35 4.53 1 6 ✓ 1
COP A2/W35 – 4.8 1
COP A-7/W35 3.18 ✓ 1 3.1 1
Noise
Outdoor unit sound power 60 dB(A) 1 53 dB(A) ✓ 1
Indoor unit sound power 46 dB(A) 1 40 dB(A) ✓ 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant GWP 3 2 3 3
Refrigerant charge 1.05 kg ✓ 1 2 kg 1
Electrical
Max. power input 5.85 kW 1 1.46 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026