Heat pumps · Compare

Shenling HPM-V150W/R3 vs Tecalor TTL 12.6 AC

SCOP (35 °C): Shenling HPM-V150W/R3 4.73, Tecalor TTL 12.6 AC 4.35. The Shenling HPM-V150W/R3 is better on 8 of 14 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • Shenling HPM-V150W/R3
  • Tecalor TTL 12.6 AC
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Shenling HPM-V150W/R3 77, Tecalor TTL 12.6 AC 66; Efficiency: Shenling HPM-V150W/R3 37, Tecalor TTL 12.6 AC 23; Noise: Shenling HPM-V150W/R3 37, Tecalor TTL 12.6 AC 47; Refrigerant: Shenling HPM-V150W/R3 66, Tecalor TTL 12.6 AC 16; Connectivity & smart: Shenling HPM-V150W/R3 50, Tecalor TTL 12.6 AC 50

Biggest differences

FactHPM-V150W/R3TTL 12.6 AC
Refrigerant GWP3698
Refrigerant charge1.4 kg5 kg
Heating capacity (A7/W35)15 kW8.24 kW
COP A2/W354.373.82
COP A-7/W352.743
Seasonal efficiency ηs 35 °C186 %171 %
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsShenlingHPM-V150W/R3TecalorTTL 12.6 AC
Grants & market
SEAI Heat Pump System Grant€14,500€14,500
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)15 kW✓28.24 kW3
Rated output 35 °C14 kW414 kW5
Rated output 55 °C14 kW415 kW✓5
Min. outdoor temperature-22 °C2–
Efficiency
SCOP (35 °C)4.73✓44.355
SCOP (55 °C)3.73✓43.555
Seasonal efficiency ηs 35 °C186 %✓4171 %5
Seasonal efficiency ηs 55 °C146 %✓4139 %5
Energy label 35 °CA+++4A++5
Energy label 55 °CA++4A++5
COP A7/W354.514.61✓1
COP A2/W354.37✓13.821
COP A-7/W352.7413✓1
Noise
Outdoor unit sound power57 dB(A)455 dB(A)✓5
Refrigerant
RefrigerantR2901R452B1
Refrigerant GWP3✓26983
Refrigerant charge1.4 kg✓15 kg1
Electrical
Max. power input6.4 kW17.1 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the Shenling HPM-V150W/R3 or the Tecalor TTL 12.6 AC?

SCOP (35 °C): Shenling HPM-V150W/R3 4.73, Tecalor TTL 12.6 AC 4.35. The Shenling HPM-V150W/R3 is better on 8 of 14 comparable points.

What is the SCOP (35 °C) of the Shenling HPM-V150W/R3 and the Tecalor TTL 12.6 AC?

Shenling HPM-V150W/R3: 4.73. Tecalor TTL 12.6 AC: 4.35.

Which is better on refrigerant GWP: the Shenling HPM-V150W/R3 or the Tecalor TTL 12.6 AC?

Shenling HPM-V150W/R3: 3. Tecalor TTL 12.6 AC: 698.

Which is better on refrigerant charge: the Shenling HPM-V150W/R3 or the Tecalor TTL 12.6 AC?

Shenling HPM-V150W/R3: 1.4 kg. Tecalor TTL 12.6 AC: 5 kg.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  5. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026