SCOP (35 °C): Shenling HPM-V150W/R3 4.73, Power World PW060-DKZLRS-E/S 4.72. The Shenling HPM-V150W/R3 is better on 8 of 13 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • Shenling HPM-V150W/R3
  • Power World PW060-DKZLRS-E/S
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Shenling HPM-V150W/R3 77, Power World PW060-DKZLRS-E/S 73; Efficiency: Shenling HPM-V150W/R3 35, Power World PW060-DKZLRS-E/S 35; Noise: Shenling HPM-V150W/R3 37, Power World PW060-DKZLRS-E/S 41; Refrigerant: Shenling HPM-V150W/R3 66, Power World PW060-DKZLRS-E/S 64; Connectivity & smart: Shenling HPM-V150W/R3 50, Power World PW060-DKZLRS-E/S 50

Biggest differences

FactHPM-V150W/R3PW060-DKZLRS-E/S
COP A-7/W352.743.02
Heating capacity (A7/W35)15 kW13.97 kW
Refrigerant charge1.4 kg1.5 kg
SCOP (55 °C)3.733.56
Seasonal efficiency ηs 55 °C146 %139.5 %
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsShenlingHPM-V150W/R3Power WorldPW060-DKZLRS-E/S
Grants & market
SEAI Heat Pump System Grant€14,500€14,500
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)15 kW✓213.97 kW3
Rated output 35 °C14 kW✓413.97 kW1
Rated output 55 °C14 kW✓413.99 kW1
Min. outdoor temperature-22 °C2–
Efficiency
SCOP (35 °C)4.73✓44.721
SCOP (55 °C)3.73✓43.561
Seasonal efficiency ηs 35 °C186 %✓4185.7 %1
Seasonal efficiency ηs 55 °C146 %✓4139.5 %1
Energy label 35 °CA+++4A+++3
Energy label 55 °CA++4A++3
COP A7/W354.514.58✓1
COP A2/W354.371–
COP A-7/W352.7413.02✓1
Noise
Outdoor unit sound power57 dB(A)456 dB(A)✓1
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge1.4 kg✓11.5 kg1
Electrical
Max. power input6.4 kW17.6 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the Shenling HPM-V150W/R3 or the Power World PW060-DKZLRS-E/S?

SCOP (35 °C): Shenling HPM-V150W/R3 4.73, Power World PW060-DKZLRS-E/S 4.72. The Shenling HPM-V150W/R3 is better on 8 of 13 comparable points.

What is the SCOP (35 °C) of the Shenling HPM-V150W/R3 and the Power World PW060-DKZLRS-E/S?

Shenling HPM-V150W/R3: 4.73. Power World PW060-DKZLRS-E/S: 4.72.

Which is better on COP A-7/W35: the Shenling HPM-V150W/R3 or the Power World PW060-DKZLRS-E/S?

Power World PW060-DKZLRS-E/S: 3.02. Shenling HPM-V150W/R3: 2.74.

Which is better on heating capacity (A7/W35): the Shenling HPM-V150W/R3 or the Power World PW060-DKZLRS-E/S?

Shenling HPM-V150W/R3: 15 kW. Power World PW060-DKZLRS-E/S: 13.97 kW.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026