Shenling HPM-V150W/R3 vs SolarEast BLN-015TE1
SCOP (35 °C): Shenling HPM-V150W/R3 4.73, SolarEast BLN-015TE1 5.09. The SolarEast BLN-015TE1 is better on 11 of 14 comparable points.
Last updated: + Add a model
Both models in detail
Who wins where
- Shenling HPM-V150W/R3
- SolarEast BLN-015TE1
Biggest differences
| Fact | HPM-V150W/R3 | BLN-015TE1 |
|---|---|---|
| COP A-7/W35 | 2.74 | 3.28 |
| COP A2/W35 | 4.37 | 4.93 |
| COP A7/W35 | 4.5 | 5.05 |
| Seasonal efficiency ηs 55 °C | 146 % | 158.3 % |
| SCOP (55 °C) | 3.73 | 4.03 |
| Seasonal efficiency ηs 35 °C | 186 % | 200.6 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | ShenlingHPM-V150W/R3 | SolarEastBLN-015TE1 |
|---|---|---|
| Grants & market | ||
| SEAI Heat Pump System Grant | €14,500 | €14,500 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 15 kW2 | 15.1 kW✓3 |
| Rated output 35 °C | 14 kW4 | 14.01 kW✓1 |
| Rated output 55 °C | 14 kW4 | 14.18 kW✓1 |
| Min. outdoor temperature | -22 °C2 | – |
| Efficiency | ||
| SCOP (35 °C) | 4.734 | 5.09✓1 |
| SCOP (55 °C) | 3.734 | 4.03✓1 |
| Seasonal efficiency ηs 35 °C | 186 %4 | 200.6 %✓1 |
| Seasonal efficiency ηs 55 °C | 146 %4 | 158.3 %✓1 |
| Energy label 35 °C | A+++4 | A+++3 |
| Energy label 55 °C | A++4 | A+++3 |
| COP A7/W35 | 4.51 | 5.05✓1 |
| COP A2/W35 | 4.371 | 4.93✓1 |
| COP A-7/W35 | 2.741 | 3.28✓1 |
| Noise | ||
| Outdoor unit sound power | 57 dB(A)4 | 55 dB(A)✓1 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 1.4 kg✓1 | 1.5 kg1 |
| Electrical | ||
| Max. power input | 6.4 kW1 | 7.8 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
Frequently asked questions
Which is better: the Shenling HPM-V150W/R3 or the SolarEast BLN-015TE1?
SCOP (35 °C): Shenling HPM-V150W/R3 4.73, SolarEast BLN-015TE1 5.09. The SolarEast BLN-015TE1 is better on 11 of 14 comparable points.
What is the SCOP (35 °C) of the Shenling HPM-V150W/R3 and the SolarEast BLN-015TE1?
Shenling HPM-V150W/R3: 4.73. SolarEast BLN-015TE1: 5.09.
Which is better on COP A-7/W35: the Shenling HPM-V150W/R3 or the SolarEast BLN-015TE1?
SolarEast BLN-015TE1: 3.28. Shenling HPM-V150W/R3: 2.74.
Which is better on COP A2/W35: the Shenling HPM-V150W/R3 or the SolarEast BLN-015TE1?
SolarEast BLN-015TE1: 4.93. Shenling HPM-V150W/R3: 4.37.
Related comparisons
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026