Guide · Solar inverters · Updated:

Solar inverter efficiency: peak, European and CEC-weighted explained

Inverters are efficient machines: Fraunhofer ISE puts the efficiency of new PV inverters at around 98% 1. Yet datasheets quote several different efficiency figures that cannot be compared directly. This guide explains what each one measures and which to use for a UK system.

Three figures, three questions

FigureWhat it tells youUse it for
Peak (maximum) efficiencyThe best efficiency at one favourable operating pointLittle — the inverter rarely runs there
European efficiency (η_EU)Weighted average over six load points, designed for a central-European climateComparing inverters for UK and European homes
CEC efficiency (η_CEC)Weighted average under the Californian test protocolSunnier climates; common on US and Australian datasheets

How the weighting works

An inverter rarely runs at full power. In the morning, evening and under cloud it works at part load, where efficiency is lower. Weighted figures therefore add up the efficiency at several load points, each multiplied by a weight reflecting how often that load occurs 2:

Load (% of rated)5%10%20%30%50%75%100%
European weight0.030.060.130.100.48–0.20
CEC weight–0.040.050.120.210.530.05

European efficiency puts almost half its weight on 50% load and also counts the 5% and 10% points. CEC efficiency puts over half on 75% load 2. The CEC protocol also measures at minimum, nominal and maximum DC voltage and averages all three 3. With the UK’s cloud cover and long part-load hours, the European figure is the better guide.

When comparing: only put like against like. Never compare one model’s European efficiency with another’s CEC or peak figure.

What our database shows

For all 86 inverters in our database we hold both peak and European efficiency from manufacturer datasheets:

  • Peak efficiency: 97.0% to 98.6%, median 98.2%.
  • European efficiency: 96.4% to 98.2%, median 97.35%.
  • Gap between the two: median 0.6 percentage points, but 1.7 points on one model. Judge on peak efficiency alone and you can draw the wrong conclusion.
  • 40 models (47%) reach 97.5% European efficiency or more; 15 (17%) reach 98% or more.

Larger inverters score better on average:

AC ratingModelsMedian European efficiency
Microinverters (< 1 kW)396.7%
1 to 4 kW2797.0%
above 4 to 6 kW3397.4%
above 6 kW2398.0%

The datasheets we use for these models do not state CEC efficiency; European datasheets usually give only the European figure.

What it means in kWh

One percentage point of efficiency is roughly one percent of annual output. On a system producing 3,500 kWh a year, the difference between 96.5% and 97.5% European efficiency is about 35 kWh a year. That adds up over the inverter’s life, but other factors usually matter more:

MPPT efficiency: the figure often missing

Conversion efficiency tells you how well the inverter turns DC into AC. MPPT efficiency tells you how well it finds and follows the panels’ optimum operating point, including when sunlight changes quickly. The European standard EN 50530 describes measurements of static and dynamic MPPT behaviour and combines them with conversion efficiency into an overall figure 2. Many datasheets give no MPPT efficiency, or only a single rounded number.

Hybrid inverters and batteries

In a hybrid inverter, energy also flows from the panels into the battery and from the battery into the home. The European efficiency on the datasheet only describes the path from panels to grid. Some makers quote separate figures for the battery path; compare those only with the same figure for other models.

In short

  1. Use European efficiency to compare models.
  2. A few tenths of a percent is small; sizing, shade and monitoring matter more.
  3. Compare European efficiency, MPPTs and power side by side in our inverter comparison.

Frequently asked questions

What is European efficiency?

A weighted average of an inverter’s efficiency at six load levels from 5% to 100% of rated power, with almost half the weight at 50% load. 2

What is CEC efficiency?

The weighted efficiency from the California Energy Commission test protocol. It puts more weight on high loads (53% at 75% load) and averages across three DC voltages. 2,3

Which efficiency figure should I use in the UK?

European efficiency. Its weighting includes low part-load points, which suits the UK’s frequent cloud better than the CEC or peak figure.

How much does 1 percentage point of efficiency matter?

Roughly 1% of your annual output. On a system generating 3,500 kWh a year that is about 35 kWh.

Keep comparing

All guides →

Sources

  1. Aktuelle Fakten zur Photovoltaik in Deutschland (Recent facts about photovoltaics in Germany) — Fraunhofer ISE · accessed 28 Sept 2026
  2. Development of transitional methods: determination of the efficiency of inverters (PV Expert Meeting, 31 October 2018) — European Commission, Joint Research Centre · accessed 28 Sept 2026
  3. CEC Inverter Test Protocol — Sandia National Laboratories – PV Performance Modeling Collaborative · accessed 28 Sept 2026