Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 vs Waterkotte EcoTouch Air Bloc 7008 (230V)

SCOP (35 °C): Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 4.44, Waterkotte EcoTouch Air Bloc 7008 (230V) 5. The Waterkotte EcoTouch Air Bloc 7008 (230V) is better on 11 of 16 comparable points.
Both models in detail
Who wins where
- Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
- Waterkotte EcoTouch Air Bloc 7008 (230V)
Biggest differences
| Fact | Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 | EcoTouch Air Bloc 7008 (230V) |
|---|---|---|
| Refrigerant charge | 1.2 kg | 0.8 kg |
| COP A7/W35 | 6.2 | 4.87 |
| Indoor unit sound power | 40 dB(A) | 35 dB(A) |
| Rated output 55 °C | 6.17 kW | 7 kW |
| Rated output 35 °C | 6.47 kW | 7.3 kW |
| SCOP (35 °C) | 4.44 | 5 |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | ViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 | WaterkotteEcoTouch Air Bloc 7008 (230V) |
|---|---|---|
| Grants & market | ||
| Boiler Upgrade Scheme | £7,500 – £9,000 | £7,500 – £9,000 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 5.6 kW✓2 | 5.02 kW3 |
| Rated output 35 °C | 6.47 kW1 | 7.3 kW✓1 |
| Rated output 55 °C | 6.17 kW1 | 7 kW✓1 |
| Min. outdoor temperature | -20 °C2 | -22 °C✓3 |
| Efficiency | ||
| SCOP (35 °C) | 4.441 | 5✓1 |
| SCOP (55 °C) | 3.581 | 3.85✓1 |
| Seasonal efficiency ηs 35 °C | 176 %1 | 197 %✓1 |
| Seasonal efficiency ηs 55 °C | 140 %1 | 151.2 %✓1 |
| Energy label 35 °C | A+++2 | A+++3 |
| Energy label 55 °C | A++2 | A+++3 |
| COP A7/W35 | 6.2✓1 | 4.871 |
| COP A2/W35 | 4.2✓1 | 3.871 |
| COP A-7/W35 | 31 | 3.26✓1 |
| Noise | ||
| Outdoor unit sound power | 48 dB(A)1 | 47 dB(A)✓1 |
| Indoor unit sound power | 40 dB(A)1 | 35 dB(A)✓1 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 1.2 kg1 | 0.8 kg✓1 |
| Electrical | ||
| Max. power input | 1.14 kW1 | 3.68 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
Frequently asked questions
Which is better: the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 or the Waterkotte EcoTouch Air Bloc 7008 (230V)?
SCOP (35 °C): Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 4.44, Waterkotte EcoTouch Air Bloc 7008 (230V) 5. The Waterkotte EcoTouch Air Bloc 7008 (230V) is better on 11 of 16 comparable points.
What is the SCOP (35 °C) of the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 and the Waterkotte EcoTouch Air Bloc 7008 (230V)?
Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 4.44. Waterkotte EcoTouch Air Bloc 7008 (230V): 5.
Which is better on refrigerant charge: the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 or the Waterkotte EcoTouch Air Bloc 7008 (230V)?
Waterkotte EcoTouch Air Bloc 7008 (230V): 0.8 kg. Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 1.2 kg.
Which is better on COP A7/W35: the Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001 or the Waterkotte EcoTouch Air Bloc 7008 (230V)?
Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001: 6.2. Waterkotte EcoTouch Air Bloc 7008 (230V): 4.87.
Related comparisons
- STIEBEL ELTRONWPL-A 07.2 Plus HK 230vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
- BuderusLogatherm WLW176i-7 AR EvsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
- BoschCompress CS6800iAW 7 ORM-S (AW 7 OR-S + CS6800iAW 12 M)vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
- ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001vsViessmannVitocal 250-A IDU-A AWMIW.A1.19-V052 / ODU 250-A AWMOF-251.A1.08-230-V001
- ELCOAEROTOP SPK10vsWaterkotteEcoTouch Air Bloc 7008 (230V)
- ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.08-230-V001vsWaterkotteEcoTouch Air Bloc 7008 (230V)
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026