Heat pumps · Compare

TCL THM14DFC vs Tecalor TTL 13.1 AC eco

SCOP (35 °C): TCL THM14DFC 4.93, Tecalor TTL 13.1 AC eco 4.65. The TCL THM14DFC is better on 7 of 15 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • TCL THM14DFC
  • Tecalor TTL 13.1 AC eco
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: TCL THM14DFC 73, Tecalor TTL 13.1 AC eco 59; Efficiency: TCL THM14DFC 61, Tecalor TTL 13.1 AC eco 44; Noise: TCL THM14DFC 37, Tecalor TTL 13.1 AC eco 77; Refrigerant: TCL THM14DFC 68, Tecalor TTL 13.1 AC eco 61; Connectivity & smart: TCL THM14DFC 50, Tecalor TTL 13.1 AC eco 50

Biggest differences

FactTHM14DFCTTL 13.1 AC eco
Heating capacity (A7/W35)14 kW5.56 kW
COP A7/W357.495.36
Refrigerant charge1.35 kg1.6 kg
COP A2/W354.573.91
Outdoor unit sound power57 dB(A)49 dB(A)
SCOP (35 °C)4.934.65
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsTCLTHM14DFCTecalorTTL 13.1 AC eco
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)14 kW✓25.56 kW3
Rated output 35 °C14 kW414 kW5
Rated output 55 °C14 kW414 kW5
Min. outdoor temperature-22 °C2-22 °C3
Efficiency
SCOP (35 °C)4.93✓44.655
SCOP (55 °C)3.8543.855
Seasonal efficiency ηs 35 °C194 %✓4183 %5
Seasonal efficiency ηs 55 °C151 %4151 %5
Energy label 35 °CA+++4A+++5
Energy label 55 °CA+++4A+++5
COP A7/W357.49✓15.361
COP A2/W354.57✓13.911
COP A-7/W352.78✓12.751
Noise
Outdoor unit sound power57 dB(A)449 dB(A)✓5
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge1.35 kg✓11.6 kg1
Electrical
Max. power input5.8 kW17.65 kW1
Connectivity & smart
SG ReadyYes1Yes1
Grants & market
ISDE grant (NL)4,150 €6–

Frequently asked questions

Which is better: the TCL THM14DFC or the Tecalor TTL 13.1 AC eco?

SCOP (35 °C): TCL THM14DFC 4.93, Tecalor TTL 13.1 AC eco 4.65. The TCL THM14DFC is better on 7 of 15 comparable points.

What is the SCOP (35 °C) of the TCL THM14DFC and the Tecalor TTL 13.1 AC eco?

TCL THM14DFC: 4.93. Tecalor TTL 13.1 AC eco: 4.65.

Which is better on heating capacity (A7/W35): the TCL THM14DFC or the Tecalor TTL 13.1 AC eco?

TCL THM14DFC: 14 kW. Tecalor TTL 13.1 AC eco: 5.56 kW.

Which is better on COP A7/W35: the TCL THM14DFC or the Tecalor TTL 13.1 AC eco?

TCL THM14DFC: 7.49. Tecalor TTL 13.1 AC eco: 5.36.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  5. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 18 Oct 2026
  6. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026