Heat pumps · Compare

STIEBEL ELTRON WPL-A 13.2 Trend HK 400 vs TCL THM14DFC

SCOP (35 °C): STIEBEL ELTRON WPL-A 13.2 Trend HK 400 4.65, TCL THM14DFC 4.93. The TCL THM14DFC is better on 7 of 16 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • STIEBEL ELTRON WPL-A 13.2 Trend HK 400
  • TCL THM14DFC
PerformanceEfficiencyNoiseRefrigerantConnectivity & smartGrants & market
Performance: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 59, TCL THM14DFC 73; Efficiency: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 44, TCL THM14DFC 61; Noise: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 77, TCL THM14DFC 37; Refrigerant: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 61, TCL THM14DFC 68; Connectivity & smart: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 50, TCL THM14DFC 50; Grants & market: STIEBEL ELTRON WPL-A 13.2 Trend HK 400 64, TCL THM14DFC 64

Biggest differences

FactWPL-A 13.2 Trend HK 400THM14DFC
Heating capacity (A7/W35)5.56 kW14 kW
COP A7/W355.367.49
Refrigerant charge1.6 kg1.35 kg
COP A2/W353.914.57
Outdoor unit sound power49 dB(A)57 dB(A)
SCOP (35 °C)4.654.93
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsSTIEBEL ELTRONWPL-A 13.2 Trend HK 400TCLTHM14DFC
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)5.56 kW214 kW✓3
Rated output 35 °C14 kW414 kW5
Rated output 55 °C14 kW414 kW5
Min. outdoor temperature-22 °C2-22 °C3
Efficiency
SCOP (35 °C)4.6544.93✓5
SCOP (55 °C)3.8543.855
Seasonal efficiency ηs 35 °C183 %4194 %✓5
Seasonal efficiency ηs 55 °C151 %4151 %5
Energy label 35 °CA+++4A+++5
Energy label 55 °CA+++4A+++5
COP A7/W355.3617.49✓1
COP A2/W353.9114.57✓1
COP A-7/W352.7512.78✓1
Noise
Outdoor unit sound power49 dB(A)✓457 dB(A)5
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge1.6 kg11.35 kg✓1
Electrical
Max. power input7.65 kW15.8 kW1
Connectivity & smart
SG ReadyYes1Yes1
Grants & market
ISDE grant (NL)4,150 €64,150 €7

Frequently asked questions

Which is better: the STIEBEL ELTRON WPL-A 13.2 Trend HK 400 or the TCL THM14DFC?

SCOP (35 °C): STIEBEL ELTRON WPL-A 13.2 Trend HK 400 4.65, TCL THM14DFC 4.93. The TCL THM14DFC is better on 7 of 16 comparable points.

What is the SCOP (35 °C) of the STIEBEL ELTRON WPL-A 13.2 Trend HK 400 and the TCL THM14DFC?

STIEBEL ELTRON WPL-A 13.2 Trend HK 400: 4.65. TCL THM14DFC: 4.93.

Which is better on heating capacity (A7/W35): the STIEBEL ELTRON WPL-A 13.2 Trend HK 400 or the TCL THM14DFC?

TCL THM14DFC: 14 kW. STIEBEL ELTRON WPL-A 13.2 Trend HK 400: 5.56 kW.

Which is better on COP A7/W35: the STIEBEL ELTRON WPL-A 13.2 Trend HK 400 or the TCL THM14DFC?

TCL THM14DFC: 7.49. STIEBEL ELTRON WPL-A 13.2 Trend HK 400: 5.36.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 1 Nov 2026
  5. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  6. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026
  7. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026