Inventor ATS10S/HU100S3 vs Tecalor TTL 8.5 ICS

SCOP (35 °C): Inventor ATS10S/HU100S3 5.19, Tecalor TTL 8.5 ICS 4.25. The Inventor ATS10S/HU100S3 is better on 13 of 15 comparable points.
Last updated: + Add a model
Both models in detail
Who wins where
- Inventor ATS10S/HU100S3
- Tecalor TTL 8.5 ICS
Biggest differences
| Fact | ATS10S/HU100S3 | TTL 8.5 ICS |
|---|---|---|
| Refrigerant GWP | 675 | 2,088 |
| Heating capacity (A7/W35) | 10 kW | 4.27 kW |
| Refrigerant charge | 1.65 kg | 2.6 kg |
| Outdoor unit sound power | 60 dB(A) | 48 dB(A) |
| COP A-7/W35 | 3.23 | 2.63 |
| Seasonal efficiency ηs 35 °C | 205 % | 167 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | InventorATS10S/HU100S3 | TecalorTTL 8.5 ICS |
|---|---|---|
| Grants & market | ||
| Boiler Upgrade Scheme | £7,500 – £9,000 | £7,500 – £9,000 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 10 kW✓2 | 4.27 kW3 |
| Rated output 35 °C | 9.17 kW✓1 | 9 kW4 |
| Rated output 55 °C | 7.67 kW✓1 | 7 kW4 |
| Min. outdoor temperature | -22 °C✓2 | -20 °C3 |
| Efficiency | ||
| SCOP (35 °C) | 5.19✓1 | 4.254 |
| SCOP (55 °C) | 3.5✓1 | 3.34 |
| Seasonal efficiency ηs 35 °C | 205 %✓1 | 167 %4 |
| Seasonal efficiency ηs 55 °C | 137 %✓1 | 129 %4 |
| Energy label 35 °C | A+++2 | A++4 |
| Energy label 55 °C | A++2 | A++4 |
| COP A7/W35 | 5✓1 | 4.741 |
| COP A2/W35 | – | 3.831 |
| COP A-7/W35 | 3.23✓1 | 2.631 |
| Noise | ||
| Outdoor unit sound power | 60 dB(A)1 | 48 dB(A)✓4 |
| Indoor unit sound power | 42 dB(A)✓1 | 51 dB(A)4 |
| Refrigerant | ||
| Refrigerant | R321 | R410A1 |
| Refrigerant GWP | 675✓2 | 2,0883 |
| Refrigerant charge | 1.65 kg✓1 | 2.6 kg1 |
| Electrical | ||
| Max. power input | 2.02 kW1 | 7 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
Frequently asked questions
Which is better: the Inventor ATS10S/HU100S3 or the Tecalor TTL 8.5 ICS?
SCOP (35 °C): Inventor ATS10S/HU100S3 5.19, Tecalor TTL 8.5 ICS 4.25. The Inventor ATS10S/HU100S3 is better on 13 of 15 comparable points.
What is the SCOP (35 °C) of the Inventor ATS10S/HU100S3 and the Tecalor TTL 8.5 ICS?
Inventor ATS10S/HU100S3: 5.19. Tecalor TTL 8.5 ICS: 4.25.
Which is better on refrigerant GWP: the Inventor ATS10S/HU100S3 or the Tecalor TTL 8.5 ICS?
Inventor ATS10S/HU100S3: 675. Tecalor TTL 8.5 ICS: 2,088.
Which is better on heating capacity (A7/W35): the Inventor ATS10S/HU100S3 or the Tecalor TTL 8.5 ICS?
Inventor ATS10S/HU100S3: 10 kW. Tecalor TTL 8.5 ICS: 4.27 kW.
Related comparisons
- InventorATS10S/HU100S3vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.10-230-V001
- ShenlingHPM-V90W/R3vsInventorATS10S/HU100S3
- AxenKS-90W/EN7BPvsInventorATS10S/HU100S3
- InventorATS10S/HU100S3vsTecalorTTL 8.5 IKCS
- InventorATS10S/HU100S3vsSTIEBEL ELTRONWPL 17 IKCS classic
- InventorATS10S/HU100S3vsSTIEBEL ELTRONWPL 17 ICS classic
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026