Heat pumps · Compare

Shenling HPM-V90W/R3 vs Inventor ATS10S/HU100S3

SCOP (35 °C): Shenling HPM-V90W/R3 5.15, Inventor ATS10S/HU100S3 5.19. Both models win equally often (6 of 14 points).

Last updated: + Add a model

Both models in detail

Who wins where

  • Shenling HPM-V90W/R3
  • Inventor ATS10S/HU100S3
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Shenling HPM-V90W/R3 49, Inventor ATS10S/HU100S3 48; Efficiency: Shenling HPM-V90W/R3 60, Inventor ATS10S/HU100S3 57; Noise: Shenling HPM-V90W/R3 47, Inventor ATS10S/HU100S3 23; Refrigerant: Shenling HPM-V90W/R3 80, Inventor ATS10S/HU100S3 41; Connectivity & smart: Shenling HPM-V90W/R3 50, Inventor ATS10S/HU100S3 50

Biggest differences

FactHPM-V90W/R3ATS10S/HU100S3
Refrigerant GWP3675
Refrigerant charge0.92 kg1.65 kg
Rated output 55 °C9 kW7.67 kW
Heating capacity (A7/W35)9 kW10 kW
Seasonal efficiency ηs 55 °C150 %137 %
SCOP (55 °C)3.833.5
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsShenlingHPM-V90W/R3InventorATS10S/HU100S3
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)9 kW210 kW✓3
Rated output 35 °C9 kW49.17 kW✓1
Rated output 55 °C9 kW✓47.67 kW1
Min. outdoor temperature-22 °C2-22 °C3
Efficiency
SCOP (35 °C)5.1545.19✓1
SCOP (55 °C)3.83✓43.51
Seasonal efficiency ηs 35 °C203 %4205 %✓1
Seasonal efficiency ηs 55 °C150 %✓4137 %1
Energy label 35 °CA+++4A+++3
Energy label 55 °CA++4A++3
COP A7/W354.8515✓1
COP A2/W354.851–
COP A-7/W352.9713.23✓1
Noise
Outdoor unit sound power55 dB(A)✓460 dB(A)1
Indoor unit sound power–42 dB(A)1
Refrigerant
RefrigerantR2901R321
Refrigerant GWP3✓26753
Refrigerant charge0.92 kg✓11.65 kg1
Electrical
Max. power input4.1 kW12.02 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the Shenling HPM-V90W/R3 or the Inventor ATS10S/HU100S3?

SCOP (35 °C): Shenling HPM-V90W/R3 5.15, Inventor ATS10S/HU100S3 5.19. Both models win equally often (6 of 14 points).

What is the SCOP (35 °C) of the Shenling HPM-V90W/R3 and the Inventor ATS10S/HU100S3?

Shenling HPM-V90W/R3: 5.15. Inventor ATS10S/HU100S3: 5.19.

Which is better on refrigerant GWP: the Shenling HPM-V90W/R3 or the Inventor ATS10S/HU100S3?

Shenling HPM-V90W/R3: 3. Inventor ATS10S/HU100S3: 675.

Which is better on refrigerant charge: the Shenling HPM-V90W/R3 or the Inventor ATS10S/HU100S3?

Shenling HPM-V90W/R3: 0.92 kg. Inventor ATS10S/HU100S3: 1.65 kg.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 28 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026