Heat pumps · Compare

CHOFU AEYC-1049ZU-CH1 vs Fairland iGXC11

SCOP (35 °C): CHOFU AEYC-1049ZU-CH1 4.67, Fairland iGXC11 5.19. The Fairland iGXC11 is better on 9 of 15 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • CHOFU AEYC-1049ZU-CH1
  • Fairland iGXC11
PerformanceEfficiencyNoiseRefrigerantConnectivity & smartGrants & market
Performance: CHOFU AEYC-1049ZU-CH1 57, Fairland iGXC11 54; Efficiency: CHOFU AEYC-1049ZU-CH1 32, Fairland iGXC11 76; Noise: CHOFU AEYC-1049ZU-CH1 52, Fairland iGXC11 67; Refrigerant: CHOFU AEYC-1049ZU-CH1 75, Fairland iGXC11 71; Connectivity & smart: CHOFU AEYC-1049ZU-CH1 50, Fairland iGXC11 50; Grants & market: CHOFU AEYC-1049ZU-CH1 42, Fairland iGXC11 42

Biggest differences

FactAEYC-1049ZU-CH1iGXC11
COP A2/W353.815.03
COP A-7/W352.443.13
Rated output 55 °C11 kW9.6 kW
Refrigerant charge1.15 kg1.3 kg
Seasonal efficiency ηs 35 °C184 %205 %
SCOP (35 °C)4.675.19
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsCHOFUAEYC-1049ZU-CH1FairlandiGXC11
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)10 kW210.69 kW✓3
Rated output 35 °C11 kW✓110.69 kW1
Rated output 55 °C11 kW✓19.6 kW1
Efficiency
SCOP (35 °C)4.6715.19✓1
SCOP (55 °C)3.613.93✓1
Seasonal efficiency ηs 35 °C184 %1205 %✓1
Seasonal efficiency ηs 55 °C141.2 %1154 %✓1
Energy label 35 °CA+++2A+++3
Energy label 55 °CA++2A+++3
COP A7/W354.9515.19✓1
COP A2/W353.8115.03✓1
COP A-7/W352.4413.13✓1
Noise
Outdoor unit sound power54 dB(A)151 dB(A)✓1
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge1.15 kg✓11.3 kg1
Electrical
Max. power input5.52 kW15.8 kW1
Connectivity & smart
SG ReadyYes1Yes1
Grants & market
ISDE grant (NL)3,475 €43,475 €5

Frequently asked questions

Which is better: the CHOFU AEYC-1049ZU-CH1 or the Fairland iGXC11?

SCOP (35 °C): CHOFU AEYC-1049ZU-CH1 4.67, Fairland iGXC11 5.19. The Fairland iGXC11 is better on 9 of 15 comparable points.

What is the SCOP (35 °C) of the CHOFU AEYC-1049ZU-CH1 and the Fairland iGXC11?

CHOFU AEYC-1049ZU-CH1: 4.67. Fairland iGXC11: 5.19.

Which is better on COP A2/W35: the CHOFU AEYC-1049ZU-CH1 or the Fairland iGXC11?

Fairland iGXC11: 5.03. CHOFU AEYC-1049ZU-CH1: 3.81.

Which is better on COP A-7/W35: the CHOFU AEYC-1049ZU-CH1 or the Fairland iGXC11?

Fairland iGXC11: 3.13. CHOFU AEYC-1049ZU-CH1: 2.44.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026
  5. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026