CHOFU AEYC-1049ZU-CH1 vs Fairland iGXC11
SCOP (35 °C): CHOFU AEYC-1049ZU-CH1 4.67, Fairland iGXC11 5.19. The Fairland iGXC11 is better on 9 of 15 comparable points.
Who wins where
- CHOFU AEYC-1049ZU-CH1
- Fairland iGXC11
Biggest differences
| Fact | AEYC-1049ZU-CH1 | iGXC11 |
|---|---|---|
| COP A2/W35 | 3.81 | 5.03 |
| COP A-7/W35 | 2.44 | 3.13 |
| Rated output 55 °C | 11 kW | 9.6 kW |
| Refrigerant charge | 1.15 kg | 1.3 kg |
| Seasonal efficiency ηs 35 °C | 184 % | 205 % |
| SCOP (35 °C) | 4.67 | 5.19 |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | CHOFUAEYC-1049ZU-CH1 | FairlandiGXC11 |
|---|---|---|
| Grants & market | ||
| SEAI Heat Pump System Grant | €14,500 | €14,500 |
| General | ||
| Type (source) | Air-to-water 1 | Air-to-water 1 |
| Performance | ||
| Heating capacity (A7/W35) | 10 kW 2 | 10.69 kW ✓ 3 |
| Rated output 35 °C | 11 kW ✓ 1 | 10.69 kW 1 |
| Rated output 55 °C | 11 kW ✓ 1 | 9.6 kW 1 |
| Efficiency | ||
| SCOP (35 °C) | 4.67 1 | 5.19 ✓ 1 |
| SCOP (55 °C) | 3.6 1 | 3.93 ✓ 1 |
| Seasonal efficiency ηs 35 °C | 184 % 1 | 205 % ✓ 1 |
| Seasonal efficiency ηs 55 °C | 141.2 % 1 | 154 % ✓ 1 |
| Energy label 35 °C | A, , , 2 | A, , , 3 |
| Energy label 55 °C | A, , 2 | A, , , 3 |
| COP A7/W35 | 4.95 1 | 5.19 ✓ 1 |
| COP A2/W35 | 3.81 1 | 5.03 ✓ 1 |
| COP A-7/W35 | 2.44 1 | 3.13 ✓ 1 |
| Noise | ||
| Outdoor unit sound power | 54 dB(A) 1 | 51 dB(A) ✓ 1 |
| Refrigerant | ||
| Refrigerant | R290 1 | R290 1 |
| Refrigerant GWP | 3 2 | 3 3 |
| Refrigerant charge | 1.15 kg ✓ 1 | 1.3 kg 1 |
| Electrical | ||
| Max. power input | 5.52 kW 1 | 5.8 kW 1 |
| Connectivity & smart | ||
| SG Ready | Yes 1 | Yes 1 |
| Grants & market | ||
| ISDE grant (NL) | 3,475 € 4 | 3,475 € 4 |
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 27 Sept 2026