CHOFU AEYC-0449ZU-CH1 vs JNOD JMU50HC

SCOP (35 °C): CHOFU AEYC-0449ZU-CH1 4.48, JNOD JMU50HC 4.78. The JNOD JMU50HC is better on 9 of 14 comparable points.
Last updated: + Add a model
Both models in detail
Who wins where
- CHOFU AEYC-0449ZU-CH1
- JNOD JMU50HC
Biggest differences
| Fact | AEYC-0449ZU-CH1 | JMU50HC |
|---|---|---|
| Refrigerant charge | 0.5 kg | 0.65 kg |
| Heating capacity (A7/W35) | 4 kW | 4.98 kW |
| COP A2/W35 | 3.81 | 4.64 |
| COP A-7/W35 | 2.6 | 2.99 |
| Seasonal efficiency ηs 55 °C | 129.4 % | 141.5 % |
| SCOP (55 °C) | 3.31 | 3.61 |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | CHOFUAEYC-0449ZU-CH1 | JNODJMU50HC |
|---|---|---|
| Grants & market | ||
| Boiler Upgrade Scheme | £7,500 – £9,000 | £7,500 – £9,000 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 4 kW2 | 4.98 kW✓3 |
| Rated output 35 °C | 5 kW1 | 5.02 kW✓1 |
| Rated output 55 °C | 5 kW✓1 | 4.99 kW1 |
| Efficiency | ||
| SCOP (35 °C) | 4.481 | 4.78✓1 |
| SCOP (55 °C) | 3.311 | 3.61✓1 |
| Seasonal efficiency ηs 35 °C | 176.2 %1 | 188 %✓1 |
| Seasonal efficiency ηs 55 °C | 129.4 %1 | 141.5 %✓1 |
| Energy label 35 °C | A+++2 | A+++3 |
| Energy label 55 °C | A++2 | A++3 |
| COP A7/W35 | 4.691 | 4.73✓1 |
| COP A2/W35 | 3.811 | 4.64✓1 |
| COP A-7/W35 | 2.61 | 2.99✓1 |
| Noise | ||
| Outdoor unit sound power | 54 dB(A)1 | 54 dB(A)1 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 0.5 kg✓1 | 0.65 kg1 |
| Electrical | ||
| Max. power input | 2.76 kW1 | 3.68 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
| Grants & market | ||
| ISDE grant (NL) | 2,350 €4 | – |
Frequently asked questions
Which is better: the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?
SCOP (35 °C): CHOFU AEYC-0449ZU-CH1 4.48, JNOD JMU50HC 4.78. The JNOD JMU50HC is better on 9 of 14 comparable points.
What is the SCOP (35 °C) of the CHOFU AEYC-0449ZU-CH1 and the JNOD JMU50HC?
CHOFU AEYC-0449ZU-CH1: 4.48. JNOD JMU50HC: 4.78.
Which is better on refrigerant charge: the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?
CHOFU AEYC-0449ZU-CH1: 0.5 kg. JNOD JMU50HC: 0.65 kg.
Which is better on heating capacity (A7/W35): the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?
JNOD JMU50HC: 4.98 kW. CHOFU AEYC-0449ZU-CH1: 4 kW.
Related comparisons
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026