Heat pumps · Compare

CHOFU AEYC-0449ZU-CH1 vs JNOD JMU50HC

SCOP (35 °C): CHOFU AEYC-0449ZU-CH1 4.48, JNOD JMU50HC 4.78. The JNOD JMU50HC is better on 9 of 14 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • CHOFU AEYC-0449ZU-CH1
  • JNOD JMU50HC
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: CHOFU AEYC-0449ZU-CH1 8, JNOD JMU50HC 11; Efficiency: CHOFU AEYC-0449ZU-CH1 13, JNOD JMU50HC 45; Noise: CHOFU AEYC-0449ZU-CH1 54, JNOD JMU50HC 54; Refrigerant: CHOFU AEYC-0449ZU-CH1 85, JNOD JMU50HC 84; Connectivity & smart: CHOFU AEYC-0449ZU-CH1 50, JNOD JMU50HC 50

Biggest differences

FactAEYC-0449ZU-CH1JMU50HC
Refrigerant charge0.5 kg0.65 kg
Heating capacity (A7/W35)4 kW4.98 kW
COP A2/W353.814.64
COP A-7/W352.62.99
Seasonal efficiency ηs 55 °C129.4 %141.5 %
SCOP (55 °C)3.313.61
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsCHOFUAEYC-0449ZU-CH1JNODJMU50HC
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)4 kW24.98 kW✓3
Rated output 35 °C5 kW15.02 kW✓1
Rated output 55 °C5 kW✓14.99 kW1
Efficiency
SCOP (35 °C)4.4814.78✓1
SCOP (55 °C)3.3113.61✓1
Seasonal efficiency ηs 35 °C176.2 %1188 %✓1
Seasonal efficiency ηs 55 °C129.4 %1141.5 %✓1
Energy label 35 °CA+++2A+++3
Energy label 55 °CA++2A++3
COP A7/W354.6914.73✓1
COP A2/W353.8114.64✓1
COP A-7/W352.612.99✓1
Noise
Outdoor unit sound power54 dB(A)154 dB(A)1
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge0.5 kg✓10.65 kg1
Electrical
Max. power input2.76 kW13.68 kW1
Connectivity & smart
SG ReadyYes1Yes1
Grants & market
ISDE grant (NL)2,350 €4–

Frequently asked questions

Which is better: the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?

SCOP (35 °C): CHOFU AEYC-0449ZU-CH1 4.48, JNOD JMU50HC 4.78. The JNOD JMU50HC is better on 9 of 14 comparable points.

What is the SCOP (35 °C) of the CHOFU AEYC-0449ZU-CH1 and the JNOD JMU50HC?

CHOFU AEYC-0449ZU-CH1: 4.48. JNOD JMU50HC: 4.78.

Which is better on refrigerant charge: the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?

CHOFU AEYC-0449ZU-CH1: 0.5 kg. JNOD JMU50HC: 0.65 kg.

Which is better on heating capacity (A7/W35): the CHOFU AEYC-0449ZU-CH1 or the JNOD JMU50HC?

JNOD JMU50HC: 4.98 kW. CHOFU AEYC-0449ZU-CH1: 4 kW.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  4. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed Oct 25, 2026