Heat pumps · UK

Tecalor TTC 7.5

The Tecalor TTC 7.5 is a heat pump with SCOP (35 °C) 4.85 and refrigerant R452B.1,2,3

Key figures

SCOP (35 °C)
4.853

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Refrigerant
R452B1
Official source
Type (source)
Ground source1
Official source
Rated output 35 °C
8kW3
Official source
Rated output 55 °C
9kW3
Official source
UK

Rules in the UK

Boiler Upgrade Scheme

Check conditions

£7,500 – £9,0004Fixed grant (England & Wales)

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.5,6

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 8 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 3.58. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type (source)Ground source1
Compressors11
Capacity controlkeine1
Performance
Rated output 35 °C8 kW3
Rated output 55 °C9 kW3
Efficiency
SCOP (35 °C)4.853
SCOP (55 °C)3.583
Seasonal efficiency ηs 35 °C191 %3
Seasonal efficiency ηs 55 °C140 %3
Energy label 35 °CA+++3
Energy label 55 °CA++3
Noise
Indoor unit sound power42 dB(A)3
Refrigerant
RefrigerantR452B1
Refrigerant GWP6982
Refrigerant charge0.85 kg1
Electrical
Max. power input3 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 13% of comparable models in our database (Heat pumps · Ground source · 8–10 kW; n = 22).

Rank 18 of 23

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 2 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • TTC 7.5
  • TTF 7.5

Similar models

Other brands, same type and a comparable size.

More from Tecalor

All Tecalor models (57) →

Guides on heat pumps

How we collect and check this data →

Frequently asked questions

What is the SCOP (35 °C) of the Tecalor TTC 7.5?

The SCOP (35 °C) of the Tecalor TTC 7.5 is 4.85.1,2,3

Which refrigerant does the Tecalor TTC 7.5 use?

The refrigerant of the Tecalor TTC 7.5 is R452B.1,2,3

How much Boiler Upgrade Scheme grant can you get for the Tecalor TTC 7.5?

£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2,3

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 18 Oct 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 9 Oct 2026
  4. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  5. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
  6. Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026