Samsung AE125HCTPES/EU + AE160DNYMPK/EU
The Samsung AE125HCTPES/EU + AE160DNYMPK/EU is an air-to-water heat pump with a SCOP of 4.67 (35 °C) and a sound power level of 62 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 7.1 m; against a wall 10.0 m.1,2
Key figures
Rules in the UK
Minimum distance to your neighbour
MCS 020(a) (England, permitted development since 29 May 2025)3 · 1 m in front of the centre of a neighbour’s habitable-room door or window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.
Boiler Upgrade Scheme
Check conditions£7,500 – £9,0004Fixed grant (England & Wales)
Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.5,6
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
- Rated output 10.5 kW; the scheme covers systems up to 45 kW.
- SCOP at 55 °C: 3.33. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| Compressors | 11 |
| Capacity control | drehzahlregelung1 |
| Performance | |
| Heating capacity (A7/W35) | 12.5 kW2 |
| Rated output 35 °C | 10.5 kW1 |
| Rated output 55 °C | 12.1 kW1 |
| Efficiency | |
| SCOP (35 °C) | 4.671 |
| SCOP (55 °C) | 3.331 |
| Seasonal efficiency ηs 35 °C | 184 %1 |
| Seasonal efficiency ηs 55 °C | 130 %1 |
| Energy label 35 °C | A+++2 |
| Energy label 55 °C | A++2 |
| COP A7/W35 | 4.661 |
| COP A2/W35 | 4.521 |
| COP A-7/W35 | 2.81 |
| Noise | |
| Outdoor unit sound power | 62 dB(A)1 |
| Indoor unit sound power | 42 dB(A)1 |
| Refrigerant | |
| Refrigerant | R321 |
| Refrigerant GWP | 6752 |
| Refrigerant charge | 2.7 kg1 |
| Electrical | |
| Max. power input | 7.24 kW1 |
| Connectivity & smart | |
| SG Ready | Yes1 |
How it ranks
SCOP (35 °C): better than 31% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 308).
Rank 204 of 309
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Variants
This model is registered in 5 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:
- AE125HCTPES/EU + AE160DNYMPK/EU
- AE125HCTPGS/EU + AE160DNZMPK/EU — Indoor unit sound power: 44 dB(A)
- AE125HCTPGS/EU + AE200DNWMPK/EU
- AE125HCTPGS/EU + AE200DNXMPK/EU — Indoor unit sound power: 44 dB(A)
- AE125HCTPGS/EU + MIM-E03FN
Compare with
Similar models
Other brands, same type and a comparable size.
More from Samsung
- Samsung AE160HCTPGS/EU + AE160DNYMPK/EU SCOP (35 °C): 4.64
- Samsung EHS Mono HT Quiet AE080BXYDGG/EU + AE160DNYMPK/EU SCOP (35 °C): 4.65
- Samsung AE120CXYDGK/EU + AE200DNWMPK/EU SCOP (35 °C): 4.9
- Samsung AE125DXEDGG/EU+AE160DNZSPG/EU SCOP (35 °C): 4.73
- Samsung AE125DXEDGG/EU+AE200DNXSPG/EU SCOP (35 °C): 4.73
- Samsung EHS Mono HT Quiet AE120BXYDGG/EU + AE160DNYMPK/EU SCOP (35 °C): 4.9
Guides on heat pumps
- SCOP, COP and ηs: what a heat pump’s efficiency figures mean
- Hybrid or full heat pump? The main types compared
- Heat pump noise: MCS 020(a), permitted development and where to put the unit
- Sizing a heat pump: heat loss, flow temperature and rated output
- Heat pump refrigerants: R290, R32 and R410A compared
How we collect and check this data →
Frequently asked questions
Can I install the Samsung AE125HCTPES/EU + AE160DNYMPK/EU without planning permission?
Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 62 dB(A) that indicatively means 7.1 m free-standing, 10.0 m against a wall or 14.2 m in a corner. Your MCS installer must confirm this.1,2
How much Boiler Upgrade Scheme grant can you get for the Samsung AE125HCTPES/EU + AE160DNYMPK/EU?
£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- MCS 020(a) (England, permitted development since 29 May 2025)
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
- Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026