NIBE F1355-28

The NIBE F1355-28 is a heat pump with SCOP (35 °C) 6.15 and refrigerant R407C.1
Key figures
Rules in the UK
Boiler Upgrade Scheme
Check conditions£7,500 – £9,0002Fixed grant (England & Wales)
Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.3,4
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
- Rated output 35 kW; the scheme covers systems up to 45 kW.
- SCOP at 55 °C: 4.79. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Technical specifications
| General | |
|---|---|
| Type (source) | Ground source1 |
| Performance | |
| Rated output 35 °C | 35 kW1 |
| Rated output 55 °C | 35 kW1 |
| Efficiency | |
| SCOP (35 °C) | 6.151 |
| SCOP (55 °C) | 4.791 |
| Seasonal efficiency ηs 35 °C | 243 %1 |
| Seasonal efficiency ηs 55 °C | 188 %1 |
| Energy label 35 °C | A+++1 |
| Energy label 55 °C | A+++1 |
| Noise | |
| Indoor unit sound power | 47 dB(A)1 |
| Refrigerant | |
| Refrigerant | R407C1 |
| Refrigerant GWP | 1,7741 |
| Refrigerant charge | 4.4 kg1 |
How it ranks
SCOP (35 °C): better than 89% of comparable models in our database (Heat pumps · Ground source · ≥ 14 kW; n = 123).
Rank 14 of 124
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Manufacturer documentation
- Product page
- Brochure / leaflet — NIBE F1355 – Product leaflet (PBD)
- Manual — NIBE F1355 – Installer manual (IHB)
External links to NIBE's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from NIBE
- NIBE F1345-30 SCOP (35 °C): 4.65
- NIBE S1155-25 SCOP (35 °C): 7.32
- NIBE F1345-24 SCOP (35 °C): 4.83
- NIBE F1345-40 SCOP (35 °C): 4.62
- NIBE F1355-43 SCOP (35 °C): 6.3
- NIBE F1145-17 SCOP (35 °C): 4.35
Guides on heat pumps
- SCOP, COP and ηs: what a heat pump’s efficiency figures mean
- Hybrid or full heat pump? The main types compared
- Heat pump noise: MCS 020(a), permitted development and where to put the unit
- Sizing a heat pump: heat loss, flow temperature and rated output
- Heat pump refrigerants: R290, R32 and R410A compared
How we collect and check this data →
Frequently asked questions
What is the SCOP (35 °C) of the NIBE F1355-28?
The SCOP (35 °C) of the NIBE F1355-28 is 6.15.1
Which refrigerant does the NIBE F1355-28 use?
The refrigerant of the NIBE F1355-28 is R407C.1
How much Boiler Upgrade Scheme grant can you get for the NIBE F1355-28?
£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
- Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026