IntergasXtend Monoblock 5 kW

The Intergas Xtend Monoblock 5 kW is an hybrid heat pump with a SCOP of 4.06 (35 °C) and a sound power level of 49 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 1.6 m; against a wall 2.2 m.1
Key figures
Rules in the UK
Minimum distance to your neighbour
MCS 020(a) (England, permitted development since 29 May 2025)2 · 1 m in front of the centre of a neighbour’s habitable-room door or window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.
Boiler Upgrade Scheme
Not eligibleFixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.4,5
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| System | Hybrid (with gas boiler)1 |
| Performance | |
| Heating capacity (A7/W35) | 5.04 kW1 |
| Min. outdoor temperature | -15 °C1 |
| Efficiency | |
| SCOP (35 °C) | 4.061 |
| Energy label 35 °C | A, , 1 |
| COP A7/W35 | 4.681 |
| Noise | |
| Outdoor unit sound power | 49 dB(A)1 |
| Indoor unit sound power | 32 dB(A)1 |
| Refrigerant | |
| Refrigerant | R321 |
| Refrigerant charge | 0.85 kg1 |
| Dimensions & weight | |
| Width | 968 mm1 |
| Height | 689 mm1 |
| Depth | 367 mm1 |
| Weight | 48 kg1 |
Manufacturer documentation
- Product page
- Brochure / leaflet — Intergas Xtend Monoblock – brochure met technische specificaties – 04/2024
External links to Intergas's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Frequently asked questions
Can I install the Intergas Xtend Monoblock 5 kW without planning permission?
Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 49 dB(A) that indicatively means 1.6 m free-standing, 2.2 m against a wall or 3.2 m in a corner. Your MCS installer must confirm this.1
How much Boiler Upgrade Scheme grant can you get for the Intergas Xtend Monoblock 5 kW?
Probably none. 1
Which refrigerant does the Intergas Xtend Monoblock 5 kW use?
The Intergas Xtend Monoblock 5 kW uses R32.1
Sources
- Intergas Xtend Monoblock – brochure met technische specificaties, 04/2024 — Intergas Verwarming B.V. · accessed 27 Sept 2026
- MCS 020(a) (England, permitted development since 29 May 2025)
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
- Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026