Heat pumps · UK

CTC EcoPart 7060

The CTC EcoPart 7060 is a heat pump with SCOP (35 °C) 7.81 and refrigerant R290.1

Key figures

SCOP (35 °C)
7.811

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Refrigerant
R2901
Official source
Type (source)
Ground source1
Official source
Rated output 35 °C
61.6kW1
Official source
Rated output 55 °C
54.5kW1
Official source
UK

Rules in the UK

Boiler Upgrade Scheme

Not eligible

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.3,4

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 61.6 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 5.73. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type (source)Ground source1
Performance
Rated output 35 °C61.6 kW1
Rated output 55 °C54.5 kW1
Efficiency
SCOP (35 °C)7.811
SCOP (55 °C)5.731
Seasonal efficiency ηs 35 °C305 %1
Seasonal efficiency ηs 55 °C221 %1
Energy label 35 °CA+++1
Energy label 55 °CA+++1
Noise
Indoor unit sound power48 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP31
Refrigerant charge2 kg1

How it ranks

SCOP (35 °C): better than 100% of comparable models in our database (Heat pumps · Ground source · ≥ 14 kW; n = 123).

Rank 1 of 124

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Similar models

Other brands, same type and a comparable size.

More from CTC

All CTC models (17) →

Featured in these lists

Guides on heat pumps

How we collect and check this data →

Frequently asked questions

What is the SCOP (35 °C) of the CTC EcoPart 7060?

The SCOP (35 °C) of the CTC EcoPart 7060 is 7.81.1

Which refrigerant does the CTC EcoPart 7060 use?

The refrigerant of the CTC EcoPart 7060 is R290.1

How much Boiler Upgrade Scheme grant can you get for the CTC EcoPart 7060?

Probably none. Rated output 61.6 kW; the scheme covers systems up to 45 kW.1

Sources

  1. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  2. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  3. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026