Heat pumps · UK

Carrier 30AWH014HP9

The Carrier 30AWH014HP9 is an air-to-water heat pump with a SCOP of 4.48 (35 °C) and a sound power level of 54 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 2.8 m; against a wall 4.0 m.1,2

Key figures

SCOP (35 °C)
4.481

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
54dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source
Rated output 35 °C
13.8kW1
Official source
UK

Rules in the UK

Minimum distance to your neighbour

MCS 020(a) (England, permitted development since 29 May 2025)3 · 1 m in front of the centre of a neighbour’s habitable-room door or window

Permitted development (MCS 020(a))≤ 37 dB(A) · LAeq,5min
Free-standing2.8 m
Against wall4 m
In corner5.6 m

Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.

Boiler Upgrade Scheme

Check conditions

£7,500 – £9,0004Fixed grant (England & Wales)

Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.5,6

  • Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
  • Rated output 13.8 kW; the scheme covers systems up to 45 kW.
  • SCOP at 55 °C: 3.68. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Heat pump grants in the UK explained →

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Rated output 35 °C13.8 kW1
Rated output 55 °C13.25 kW1
Efficiency
SCOP (35 °C)4.481
SCOP (55 °C)3.681
Seasonal efficiency ηs 35 °C176 %1
Seasonal efficiency ηs 55 °C144 %1
COP A7/W354.41
COP A-7/W352.741
SEER (cooling)5.151
Noise
Outdoor unit sound power54 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant GWP32
Refrigerant charge1.07 kg1
Electrical
Max. power input10.5 kW1
Connectivity & smart
SG ReadyNo1
Grants & market
ISDE grant (NL)3,025 €2

How it ranks

SCOP (35 °C): better than 9% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 308).

Rank 277 of 309

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Carrier

All Carrier models (18) →

Guides on heat pumps

How we collect and check this data →

Frequently asked questions

Can I install the Carrier 30AWH014HP9 without planning permission?

Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 54 dB(A) that indicatively means 2.8 m free-standing, 4.0 m against a wall or 5.6 m in a corner. Your MCS installer must confirm this.1,2

How much Boiler Upgrade Scheme grant can you get for the Carrier 30AWH014HP9?

£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1,2

Which refrigerant does the Carrier 30AWH014HP9 use?

The Carrier 30AWH014HP9 uses R290.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 27 Sept 2026
  3. MCS 020(a) (England, permitted development since 29 May 2025)
  4. Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
  5. Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026