Bosch CSH3800iAW 6

The Bosch CSH3800iAW 6 is an air-to-water heat pump with a SCOP of 4.87 (35 °C) and a sound power level of 48 dB(A). Under permitted development the limit is 37 dB(A) measured 1 m in front of the centre of a neighbour’s habitable-room door or window. Free-standing, the indicative minimum distance is 1.4 m; against a wall 2.0 m.1
Key figures
Rules in the UK
Minimum distance to your neighbour
MCS 020(a) (England, permitted development since 29 May 2025)2 · 1 m in front of the centre of a neighbour’s habitable-room door or window
Indicative calculation (hemispherical, no barriers). Not a substitute for an MCS 020 assessment.
Boiler Upgrade Scheme
Check conditions£7,500 – £9,0003Fixed grant (England & Wales)
Fixed grant in England and Wales, deducted from your installer’s quote. £9,000 when replacing oil or LPG off the gas grid (until March 2027). Scotland: Home Energy Scotland grant instead.4,5
- Must be MCS-certified (product and installer). Check the Ofgem product eligibility list.
- Rated output 6 kW; the scheme covers systems up to 45 kW.
- SCOP at 55 °C: 3.59. The installed system needs a SCOP of at least 2.8 (MCS calculation).
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| Performance | |
| Heating capacity (A7/W35) | 5.01 kW1 |
| Rated output 35 °C | 6 kW1 |
| Rated output 55 °C | 6 kW1 |
| Min. outdoor temperature | -22 °C1 |
| Efficiency | |
| SCOP (35 °C) | 4.871 |
| SCOP (55 °C) | 3.591 |
| Seasonal efficiency ηs 35 °C | 192 %1 |
| Seasonal efficiency ηs 55 °C | 141 %1 |
| Energy label 35 °C | A+++1 |
| Energy label 55 °C | A++1 |
| COP A7/W35 | 4.831 |
| Noise | |
| Outdoor unit sound power | 48 dB(A)1 |
| Indoor unit sound power | 34 dB(A)1 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant GWP | 31 |
| Refrigerant charge | 1.13 kg1 |
How it ranks
SCOP (35 °C): better than 65% of comparable models in our database (Heat pumps · Air-to-water · 6–8 kW; n = 175).
Rank 62 of 176
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Manufacturer documentation
- Product page
- Brochure / leaflet — Luft-Wasser-Wärmepumpe Compress 3800i AW – Broschüre
External links to Bosch's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from Bosch
- Bosch Compress 3400i AWS CS3400iAWS 6 ORB-S SCOP (35 °C): 4.63
- Bosch Compress 3800i AW CS3800iAW 6 O-S-H SCOP (35 °C): 4.69
- Bosch Compress 3800i AW CS3800iAW 6 OE-S SCOP (35 °C): 4.98
- Bosch Compress 7400i AW CS7400i AW 7 O H SCOP (35 °C): 4.61
- Bosch Compress 7400i AW CS7400iAW 7 ORE SCOP (35 °C): 5.02
- Bosch Compress 7400i AW CS7400iAW 7 ORMB SCOP (35 °C): 4.73
Guides on heat pumps
- SCOP, COP and ηs: what a heat pump’s efficiency figures mean
- Hybrid or full heat pump? The main types compared
- Heat pump noise: MCS 020(a), permitted development and where to put the unit
- Sizing a heat pump: heat loss, flow temperature and rated output
- Heat pump refrigerants: R290, R32 and R410A compared
How we collect and check this data →
Frequently asked questions
Can I install the Bosch CSH3800iAW 6 without planning permission?
Under MCS 020(a) (England, permitted development since 29 May 2025) the unit must not exceed 37 dB(A) 1 m in front of the centre of a neighbour’s habitable-room door or window. With a sound power of 48 dB(A) that indicatively means 1.4 m free-standing, 2.0 m against a wall or 2.8 m in a corner. Your MCS installer must confirm this.1
How much Boiler Upgrade Scheme grant can you get for the Bosch CSH3800iAW 6?
£7,500 in England and Wales, provided the product and installer are MCS-certified (£9,000 when replacing oil or LPG off the gas grid, until March 2027). The installer applies and deducts the grant from your quote.1
Which refrigerant does the Bosch CSH3800iAW 6 use?
The Bosch CSH3800iAW 6 uses R290.1
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- MCS 020(a) (England, permitted development since 29 May 2025)
- Boiler Upgrade Scheme: what you can get — GOV.UK · accessed 27 Sept 2026
- Boiler Upgrade Scheme: guidance for installers (V5) — Ofgem · accessed 27 Sept 2026
- Boiler Upgrade Scheme product eligibility — Ofgem · accessed 27 Sept 2026