TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 vs Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
SCOP (35 °C): TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 5,44, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 4,53. Model TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 je boljši v 9 od 15 primerljivih točk.
Oba modela podrobno
Kje je kdo boljši
- TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290
- Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
Največje razlike
| Merilo | Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 | Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 |
|---|---|---|
| Grelna moč (A7/W35) | 12,1 kW | 8,1 kW |
| Polnitev hladiva | 1,35 kg | 2 kg |
| COP A7/W35 | 4,99 | 6,1 |
| Sezonska energijska učinkovitost ηs pri 35 °C | 215 % | 178 % |
| SCOP (35 °C) | 5,44 | 4,53 |
| Sezonska energijska učinkovitost ηs pri 55 °C | 159 % | 141 % |
Ocena po merilu = položaj (0–100) glede na vse modele v tej kategoriji (skupaj 1350); višje je bolje.
| Tehnični podatki | TEMPLARIUnità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 | ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 |
|---|---|---|
| Splošno | ||
| Tip (vir toplote) | Zrak-voda1 | Zrak-voda1 |
| Moč | ||
| Grelna moč (A7/W35) | 12,1 kW✓2 | 8,1 kW3 |
| Nazivna moč pri 35 °C | 12,41 kW1 | 12,42 kW✓1 |
| Nazivna moč pri 55 °C | 11,59 kW1 | 12,1 kW✓1 |
| Najnižja zunanja temperatura | −22 °C✓2 | −20 °C3 |
| Učinkovitost | ||
| SCOP (35 °C) | 5,44✓1 | 4,531 |
| SCOP (55 °C) | 4,05✓1 | 3,61 |
| Sezonska energijska učinkovitost ηs pri 35 °C | 215 %✓1 | 178 %1 |
| Sezonska energijska učinkovitost ηs pri 55 °C | 159 %✓1 | 141 %1 |
| Energijska nalepka pri 35 °C | A+++2 | A+++3 |
| Energijska nalepka pri 55 °C | A+++2 | A++3 |
| COP A7/W35 | 4,991 | 6,1✓1 |
| COP A2/W35 | 4,231 | 4,3✓1 |
| COP A-7/W35 | 3,02✓1 | 31 |
| Hrup | ||
| Raven zvočne moči zunanje enote | 50 dB(A)✓1 | 54 dB(A)1 |
| Raven zvočne moči notranje enote | – | 40 dB(A)1 |
| Hladivo | ||
| Hladivo | R2901 | R2901 |
| GWP hladiva | 32 | 33 |
| Polnitev hladiva | 1,35 kg✓1 | 2 kg1 |
| Električni podatki | ||
| Največja priključna moč | 4,02 kW1 | 1,65 kW1 |
| Povezljivost in upravljanje | ||
| SG Ready | Da1 | Da1 |
Pogosta vprašanja
Kateri je boljši: TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001?
SCOP (35 °C): TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 5,44, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001 4,53. Model TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 je boljši v 9 od 15 primerljivih točk.
Kolikšna je vrednost SCOP (35 °C) pri TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 in Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001?
TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290: 5,44. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001: 4,53.
Kateri je boljši pri grelna moč (A7/W35): TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001?
TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290: 12,1 kW. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001: 8,1 kW.
Kateri je boljši pri polnitev hladiva: TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290 ali Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001?
TEMPLARI Unità esterna KITA-SP-12, 1Ph, vers. MONOBLOCCO R-290: 1,35 kg. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001: 2 kg.
Podobne primerjave
- ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001vsWaterkotteEcoTouch Air Bloc 7016
- TEMPLARIUNITÀ ESTERNA KITA-HRP-16, 1PH, VERS. MONOBLOCCO R-290vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
- SamsungAE125DXEDGG/EU+AE160DNZSPG/EUvsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
- SamsungAE125DXEDGG/EU+AE200DNXSPG/EUvsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
- SamsungEHS Mono HT Quiet AE120BXYDGG/EU + AE160DNYMPK/EUvsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
- TEMPLARIUnità esterna KITA-MP-16, 3Ph, vers. MONOBLOCCO R-290vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.13-230-V001
Kako zbiramo in preverjamo te podatke →
Viri
- Seznam upravičenih toplotnih črpalk (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · dostopano 27. sep. 2026
- Certifikati Heat Pump Keymark — EHPA / DIN CERTCO (Heat Pump KEYMARK) · dostopano 29. sep. 2026
- Certifikati Heat Pump Keymark — EHPA / DIN CERTCO (Heat Pump KEYMARK) · dostopano 29. sep. 2026