UnknownREWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| Compressors | 11 |
| Capacity control | Inverter1 |
| Performance | |
| Heating capacity (A7/W35) | 9.29 kW2 |
| Rated output 35 °C | 10 kW1 |
| Rated output 55 °C | 10 kW1 |
| Min. outdoor temperature | -22 °C2 |
| Efficiency | |
| SCOP (35 °C) | 4.791 |
| SCOP (55 °C) | 3.81 |
| Seasonal efficiency ηs 35 °C | 189 %1 |
| Seasonal efficiency ηs 55 °C | 149 %1 |
| Energy label 35 °C | A+++2 |
| Energy label 55 °C | A++2 |
| COP A7/W35 | 4.581 |
| COP A2/W35 | 3.731 |
| COP A-7/W35 | 3.121 |
| Noise | |
| Outdoor unit sound power | 49 dB(A)1 |
| Indoor unit sound power | 46 dB(A)1 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant GWP | 32 |
| Refrigerant charge | 1.37 kg1 |
| Electrical | |
| Max. power input | 4.7 kW1 |
| Connectivity & smart | |
| SG Ready | Yes1 |
How it ranks
SCOP (35 °C): better than 51% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).
Rank 148 of 310
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Manufacturer documentation
- Product page
- Brochure / leaflet — Logatherm WLW166i Luft-Wasser-Wärmepumpe – Broschüre
- Brochure / leaflet — Logatherm WLW166i SP AR EinbauCheck – Fachinformation
External links to Buderus's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from Buderus
- Buderus Hybrid-Set WLW196i-11 A H SCOP (35 °C): 4.92
- Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) SCOP (35 °C): 5.01
- Buderus Logaplus M WLW176i-10 AR E (Logatherm WLW-10 MB AR + WLW176i-12 E) SCOP (35 °C): 4.8
- Buderus Logaplus M WLW176i-10 AR TP70 (Logatherm WLW-10 MB AR + WLW176i-12 TP70) SCOP (35 °C): 4.74
- Buderus Logatherm WLW176i-10 AR E SCOP (35 °C): 4.77
- Buderus Logatherm WLW176i-10 AR T180 SCOP (35 °C): 4.73
How we collect and check this data →
Frequently asked questions
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 08 Nov 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)