The Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) is an air-to-water heat pump with a SCOP of 5.01 (35 °C) and a sound power level of 49 dB(A).1

Key figures

SCOP (35 °C)
5.011

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Outdoor unit sound power
49dB(A)1
Official source
Refrigerant
R2901
Official source
Type (source)
Air-to-water1
Official source
Rated output 35 °C
10kW1
Official source
MT

Rules in Malta

Water Heater Scheme (heat pump water heaters)

Unknown

REWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controlInverter1
Performance
Rated output 35 °C10 kW1
Rated output 55 °C10 kW1
Efficiency
SCOP (35 °C)5.011
SCOP (55 °C)3.931
Seasonal efficiency ηs 35 °C197 %1
Seasonal efficiency ηs 55 °C154 %1
COP A7/W354.731
COP A2/W353.821
COP A-7/W353.191
SEER (cooling)4.461
Noise
Outdoor unit sound power49 dB(A)1
Indoor unit sound power34 dB(A)1
Refrigerant
RefrigerantR2901
Refrigerant charge1.37 kg1
Electrical
Max. power input4.7 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 74% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).

Rank 77 of 310

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Variants

This model is registered in 4 combinations (for example with a different indoor unit or cylinder) with exactly the same performance. All figures on this page apply to each of these types. The part of the type number that differs is in bold; small differences (e.g. cylinder volume or anode) are listed after it:

  • Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E)
  • Logaplus WP400 WLW166i MBB T (WLW-10 MBB AR P3 & Logatherm WLW166i MBB T180, Zubehör) — Indoor unit sound power: 40 dB(A)
  • Logaplus WP401 WLW166i MBB E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E, Zubehör)
  • Logaplus M WLW166i-10 MBB AR T180 (WLW-10 MBB AR P3 & Logatherm WLW166i MBB T180) — Indoor unit sound power: 40 dB(A)

Manufacturer documentation

External links to Buderus's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Buderus

All Buderus models (100) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) use?

The Buderus Logaplus M WLW166i-10 MBB AR E (WLW-10 MBB AR P3 & Logatherm WLW176i.2 E) uses R290.1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)