Heat pump water heaters
Compare 450 heat pump water heaters on water heating efficiency ηwh, load profile, energy class, annual consumption and noise per heat pump water heater…
ENERGIE AQUAPURA BOOSTER 200I
- ηwh
- 226 %
- Load profile
- L
- Energy label
- A+
- Annual use
- 556 kWh
- Noise indoor
- 45 dB(A)
- Noise outdoor
- –
- Smart: unknown
ENERGIE AQUAPURA BOOSTER 300I
- ηwh
- 226 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- 833 kWh
- Noise indoor
- 45 dB(A)
- Noise outdoor
- –
- Smart: unknown
Eco Hot Water 01-05 150l
- ηwh
- 225 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Oekoboiler ZG 02-05 150l
- ηwh
- 225 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Eco Hot Water 01-05 200l
- ηwh
- 215 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Oekoboiler ZG 02-05 200l
- ηwh
- 215 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Eco Hot Water 01-05 300l
- ηwh
- 206 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Oekoboiler ZG 02-05 300l
- ηwh
- 206 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 46 dB(A)
- Noise outdoor
- –
- Smart: yes
Zestar HS04V-Q
- ηwh
- 195 %
- Load profile
- M
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 55 dB(A)
- Smart: yes
Zestar HS06V-Q
- ηwh
- 195 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 59 dB(A)
- Smart: yes
Zestar HS10V-Q
- ηwh
- 192 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 58 dB(A)
- Smart: yes
Zestar HS12V-Q
- ηwh
- 192 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 60 dB(A)
- Smart: yes
Zestar HS08V-Q
- ηwh
- 186 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 56 dB(A)
- Smart: yes
Migloor PAVH-15V4FBA
- ηwh
- 185 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 40 dB(A)
- Noise outdoor
- 61 dB(A)
- Smart: yes
Eco Hot Water 01-05 350l
- ηwh
- 181 %
- Load profile
- XXL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 50 dB(A)
- Noise outdoor
- –
- Smart: unknown
Oekoboiler ZG 02-05 350l
- ηwh
- 181 %
- Load profile
- XXL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 50 dB(A)
- Noise outdoor
- –
- Smart: unknown
Dimplex Edel 200 Water - Water D893332
- ηwh
- 179 %
- Load profile
- M
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 44 dB(A)
- Noise outdoor
- –
- Smart: unknown
intuis 352231 - Edel 150 EAU /3
- ηwh
- 179 %
- Load profile
- M
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 44 dB(A)
- Noise outdoor
- –
- Smart: unknown
intuis 352431 - Edel 270 EAU /3
- ηwh
- 179 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 44 dB(A)
- Noise outdoor
- –
- Smart: unknown
Tiki DHW W 300
- ηwh
- 179 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 41 dB(A)
- Noise outdoor
- –
- Smart: unknown
SOLIUS QSWHA160L
- ηwh
- 178 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- –
- Noise outdoor
- 53 dB(A)
- Smart: unknown
STIEBEL ELTRON SHP-I 300 H Plus
- ηwh
- 177 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 59 dB(A)
- Noise outdoor
- –
- Smart: unknown
Ochsner EUROPA N 200 CA
- ηwh
- 176 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 59 dB(A)
- Noise outdoor
- –
- Smart: unknown
STIEBEL ELTRON SHP-I 200 Plus
- ηwh
- 176 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 57 dB(A)
- Noise outdoor
- –
- Smart: unknown
STIEBEL ELTRON SHP-O 200 Plus
- ηwh
- 176 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 59 dB(A)
- Noise outdoor
- –
- Smart: unknown
Tecalor TTA 200.1 comfort
- ηwh
- 176 %
- Load profile
- L
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 57 dB(A)
- Noise outdoor
- –
- Smart: unknown
Viessmann 7959724 Viessmann DHW Booster HP 170L 1.2 kW
- ηwh
- 176 %
- Load profile
- M
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 45 dB(A)
- Noise outdoor
- –
- Smart: unknown
Kronoterm ESSENTA-303/1 E D PV P3 (EPREL 2659109)
- ηwh
- 172 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 55 dB(A)
- Noise outdoor
- –
- Smart: unknown
Metro Therm METRO MICROBOOSTER P 260
- ηwh
- 172 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 43 dB(A)
- Noise outdoor
- –
- Smart: unknown
Ochsner EUROPA N 300 CA
- ηwh
- 172 %
- Load profile
- XL
- Energy label
- A+
- Annual use
- –
- Noise indoor
- 59 dB(A)
- Noise outdoor
- –
- Smart: unknown
| Compare | Features |
|---|
No models match these filters.
Green = yes · struck through = no · dashed = unknown
All models by brand
AERMEC 1
AIRE 1
AIRTHERMIA 4
Airwell 2
ALDES 2
AMG 1
ARGO 1
ARISTON 5
ASTON 1
ATAG 3
Baetulenn 6
Baxi 3
Brötje 1
Carrier 4
Chaffoteaux 5
Chappee 4
Clivet 4
CM 5
CM REPRESENTAÇÕES 3
Cointra 5
Cooper&Hunter 1
Cordivari 1
Daikin 6
DAITSU 5
De Dietrich 5
DeWarmte 1
Dimplex 5
DOMUSA TEKNIK 1
Durafy 1
ELCO 4
Electranova 1
ENERGIE 5
Fiorini 1
FREEO 1
FUJIKO 1
Galmet 1
Goodheat 5
Gree 5
HDG Bavaria 1
Heatcomp 1
Hedatech 1
HEWALEX 1
Hitachi 3
Hoval 1
Immergas 5
Indol 8
intuis 4
Inventum 4
Itho Daalderop 7
Jiadele 5
Kronoterm 3
KWB 1
Lamborghini Caloreclima 2
LG 1
Midea 4
Migloor 1
Mitsubishi Electric 1
Mitsubishi Heavy Industries 1
MUNDOCLIMA 5
NØRDIS 1
Nuova 1
Ochsner 2
Oekoboiler 5
Oertli 4
OLIMPIA SPLENDID 3
ORCA 1
OUTES 2
Renson 1
RP Handels 1
Saunier Duval 5
SINCLAIR 1
SOLIUS 5
STIEBEL ELTRON 5
Sunex 2
TCL 1
TEPOR 1
TESY 1
THERVIO 1
Toshiba 4
Tulip Wise 1
Vaillant 2
Warmichko 1
Waterkotte 2
Windhager 1
Selections
Popular comparisons
- GoodheatGHWSVT-300AA1vsNuovaWPB275AG-MB
- NuovaWPB275AG-MBvsWEBER X300-1W
- AirwellTFHM-100H-04M25vsAUSTRIA EMAIL964053
- AUSTRIA EMAIL976043vsBaetulenn[BLCCVE200G] BAELUC B10 200L
- AUSTRIA EMAIL986137vsBaetulenn[BLCCVE200G] BAELUC B10 200L
- Baetulenn[BLCCVE300G] BAELUC B10 300LvsBosch7738340429
- Baetulenn[BLCDAE500A] BAELUC B30 500LvsBosch7738340429
- AirwellTFHM-100H-04M25vsBaetulenn[BLCSVE120G] BAELUC B10 120L
- AirwellTFHM-100H-04M25vsBosch7724001868
- AUSTRIA EMAIL976043vsBosch7724001871
- AirwellTFHM-100H-04M25vsBosch7738340431
- AirwellTFHM-100H-04M25vsBuderus7724000203
Heat pump water heater or heat pump: what is the difference?
A heat pump water heater does one job: it heats tap water. The unit sits on or next to a storage tank, takes heat from the air around it – the room, the outside air or the ventilation exhaust – and keeps the hot water ready for showers and taps. A regular heat pump heats the whole home through radiators or underfloor heating and is sized in kilowatts for the heat demand of the building. Many homes have one without the other.
The two are also rated differently. A space-heating heat pump is described by its seasonal efficiency (SCOP) and its output in kW. A heat pump water heater has its own energy label under EU regulation 812/2013 with the water heating efficiency ηwh, an energy class, the declared load profile and the annual electricity use. Because ηwh is measured against primary energy, a good heat pump water heater scores well above 100%, while an ordinary electric boiler stays far below it. The load profile, from 3XS (hand washing) to 4XL (large household or business), shows which tapping pattern the figures belong to: compare ηwh and annual use only within the same profile.
The register behind these pages does not list tank volume, heating-up time or electrical power, so check the manufacturer’s datasheet for those before you buy. If you already have a heat pump for space heating, first see whether it can serve a hot-water cylinder; a separate heat pump water heater mostly makes sense when you replace an electric boiler or gas water heater, or when there is no central heat pump.
When choosing, also consider noise and location. Indoor sound power matters if the unit stands in a utility room, laundry room or next to a bedroom; for a model with an outdoor unit, the outdoor noise matters too. A unit that takes heat from the room itself cools that room down, which makes little difference in an unheated basement or garage but does in a living space. Smart control lets the water heater run mainly when your own solar power or cheaper electricity is available.
Sources
- European Product Registry for Energy Labelling (EPREL) – water heaters — Europese Commissie · accessed 08 Nov 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 18 Oct 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 08 Nov 2026
Image: Oekoboiler
Image: Oekoboiler
Image: Oekoboiler
Image: Oekoboiler
Image: STIEBEL ELTRON
Image: STIEBEL ELTRON
Image: STIEBEL ELTRON