Heat pumps · Compare

Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE vs Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L]

SCOP (35 °C): Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 3.92, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 4.25. The Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] is better on 12 of 14 comparable points.

Who wins where

  • Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE
  • Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L]
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 88, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 89; Efficiency: Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 20, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 29; Noise: Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 17, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 60; Refrigerant: Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 5, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 18; Connectivity & smart: Mitsubishi Electric PUHZ-SHW230YKA2 + ERSE-YM9EE 50, Panasonic AQUAREA [WH-WXG25ME8 + WH-CME8L] 50

Biggest differences

FactPUHZ-SHW230YKA2 + ERSE-YM9EEAQUAREA [WH-WXG25ME8 + WH-CME8L]
Refrigerant charge7.1 kg3 kg
COP A-7/W353.342.42
Indoor unit sound power45 dB(A)35 dB(A)
COP A2/W353.344.24
COP A7/W353.654.5
Outdoor unit sound power68 dB(A)58 dB(A)
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications Mitsubishi ElectricPUHZ-SHW230YKA2 + ERSE-YM9EE PanasonicAQUAREA [WH-WXG25ME8 + WH-CME8L]
Grants & market
SEAI Heat Pump System Grant €14,500€14,500
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Rated output 35 °C 23 kW 1 25 kW ✓ 1
Rated output 55 °C 23 kW 1 25 kW ✓ 1
Efficiency
SCOP (35 °C) 3.92 1 4.25 ✓ 1
SCOP (55 °C) 3.2 1 3.58 ✓ 1
Seasonal efficiency ηs 35 °C 154 % 1 167 % ✓ 1
Seasonal efficiency ηs 55 °C 125 % 1 140 % ✓ 1
COP A7/W35 3.65 1 4.5 ✓ 1
COP A2/W35 3.34 1 4.24 ✓ 1
COP A-7/W35 3.34 ✓ 1 2.42 1
SEER (cooling) 4.32 1 4.58 ✓ 1
Noise
Outdoor unit sound power 68 dB(A) 1 58 dB(A) ✓ 1
Indoor unit sound power 45 dB(A) 1 35 dB(A) ✓ 1
Refrigerant
Refrigerant R410A 1 R290 1
Refrigerant charge 7.1 kg 1 3 kg ✓ 1
Electrical
Max. power input 13.16 kW 1 15.1 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026