SCOP (35 °C): M-TEC AHPA413 5.5, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 4.59. The M-TEC AHPA413 is better on 9 of 14 comparable points.

Who wins where

  • M-TEC AHPA413
  • STIEBEL ELTRON WPL-A 10.2 Trend HK 230
PerformanceEfficiencyNoiseRefrigerantConnectivity & smartGrants & market
Performance: M-TEC AHPA413 51, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 51; Efficiency: M-TEC AHPA413 90, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 45; Noise: M-TEC AHPA413 85, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 81; Refrigerant: M-TEC AHPA413 47, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 70; Connectivity & smart: M-TEC AHPA413 50, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 50; Grants & market: M-TEC AHPA413 42, STIEBEL ELTRON WPL-A 10.2 Trend HK 230 42

Biggest differences

FactAHPA413WPL-A 10.2 Trend HK 230
Refrigerant charge3.1 kg1.4 kg
COP A2/W355.473.96
SCOP (35 °C)5.54.59
Seasonal efficiency ηs 35 °C216 %181 %
COP A-7/W353.342.8
Seasonal efficiency ηs 55 °C169 %148 %
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications M-TECAHPA413 STIEBEL ELTRONWPL-A 10.2 Trend HK 230
Grants & market
SEAI Heat Pump System Grant €14,500€14,500
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) – 4.26 kW 2
Rated output 35 °C 10.67 kW ✓ 1 10.64 kW 1
Rated output 55 °C 10.45 kW 1 10.62 kW ✓ 1
Min. outdoor temperature – -22 °C 2
Efficiency
SCOP (35 °C) 5.5 ✓ 1 4.59 1
SCOP (55 °C) 4.3 ✓ 1 3.78 1
Seasonal efficiency ηs 35 °C 216 % ✓ 1 181 % 1
Seasonal efficiency ηs 55 °C 169 % ✓ 1 148 % 1
Energy label 35 °C – A, , , 2
Energy label 55 °C – A, , 2
COP A7/W35 5.47 ✓ 1 5.4 1
COP A2/W35 5.47 ✓ 1 3.96 1
COP A-7/W35 3.34 ✓ 1 2.8 1
Noise
Outdoor unit sound power 46 dB(A) ✓ 1 48 dB(A) 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant GWP 3 3 3 2
Refrigerant charge 3.1 kg 1 1.4 kg ✓ 1
Electrical
Max. power input 5.8 kW 1 4.6 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1
Grants & market
ISDE grant (NL) 3,250 € 3 3,250 € 3