Heat pumps · Compare

Inventor ATS08S/HU100S3 vs Power World PW040-DKZLRS-E1/S(ODU)

SCOP (35 °C): Inventor ATS08S/HU100S3 5.21, Power World PW040-DKZLRS-E1/S(ODU) 4.92. The Power World PW040-DKZLRS-E1/S(ODU) is better on 7 of 15 comparable points.

Who wins where

  • Inventor ATS08S/HU100S3
  • Power World PW040-DKZLRS-E1/S(ODU)
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Inventor ATS08S/HU100S3 37, Power World PW040-DKZLRS-E1/S(ODU) 40; Efficiency: Inventor ATS08S/HU100S3 66, Power World PW040-DKZLRS-E1/S(ODU) 66; Noise: Inventor ATS08S/HU100S3 38, Power World PW040-DKZLRS-E1/S(ODU) 65; Refrigerant: Inventor ATS08S/HU100S3 46, Power World PW040-DKZLRS-E1/S(ODU) 84; Connectivity & smart: Inventor ATS08S/HU100S3 50, Power World PW040-DKZLRS-E1/S(ODU) 50

Biggest differences

FactATS08S/HU100S3PW040-DKZLRS-E1/S(ODU)
Refrigerant GWP6753
Refrigerant charge1.65 kg0.9 kg
Rated output 55 °C6.6 kW8.25 kW
Seasonal efficiency ηs 55 °C132 %153.4 %
Outdoor unit sound power59 dB(A)51 dB(A)
SCOP (55 °C)3.383.91
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications InventorATS08S/HU100S3 Power WorldPW040-DKZLRS-E1/S(ODU)
Grants & market
SEAI Heat Pump System Grant €14,500€14,500
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) 8.3 kW ✓ 2 8.1 kW 3
Rated output 35 °C 8.12 kW 1 8.12 kW 1
Rated output 55 °C 6.6 kW 1 8.25 kW ✓ 1
Min. outdoor temperature -22 °C 2 –
Efficiency
SCOP (35 °C) 5.21 ✓ 1 4.92 1
SCOP (55 °C) 3.38 1 3.91 ✓ 1
Seasonal efficiency ηs 35 °C 205 % ✓ 1 193.8 % 1
Seasonal efficiency ηs 55 °C 132 % 1 153.4 % ✓ 1
Energy label 35 °C A, , , 2 A, , , 3
Energy label 55 °C A, , 2 A, , , 3
COP A7/W35 5.2 ✓ 1 4.81 1
COP A2/W35 5.09 ✓ 1 4.77 1
COP A-7/W35 3.35 ✓ 1 3.28 1
Noise
Outdoor unit sound power 59 dB(A) 1 51 dB(A) ✓ 1
Indoor unit sound power 42 dB(A) 1 40 dB(A) ✓ 1
Refrigerant
Refrigerant R32 1 R290 1
Refrigerant GWP 675 2 3 ✓ 3
Refrigerant charge 1.65 kg 1 0.9 kg ✓ 1
Electrical
Max. power input 1.63 kW 1 2.71 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 28 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026