Heat pumps · Compare

TCL THM16DFC vs Tulip Wise Tulip Next 18.3

SCOP (35 °C): TCL THM16DFC 4.83, Tulip Wise Tulip Next 18.3 4.78. The TCL THM16DFC is better on 7 of 15 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • TCL THM16DFC
  • Tulip Wise Tulip Next 18.3
PerformanceEfficiencyNoiseRefrigerantConnectivity & smartGrants & market
Performance: TCL THM16DFC 83, Tulip Wise Tulip Next 18.3 85; Efficiency: TCL THM16DFC 56, Tulip Wise Tulip Next 18.3 50; Noise: TCL THM16DFC 27, Tulip Wise Tulip Next 18.3 41; Refrigerant: TCL THM16DFC 68, Tulip Wise Tulip Next 18.3 66; Connectivity & smart: TCL THM16DFC 50, Tulip Wise Tulip Next 18.3 50; Grants & market: TCL THM16DFC 69, Tulip Wise Tulip Next 18.3 71

Biggest differences

FactTHM16DFCTulip Next 18.3
COP A7/W357.464.6
COP A-7/W352.73.57
Heating capacity (A7/W35)16 kW18.42 kW
Rated output 55 °C15 kW16 kW
Outdoor unit sound power59 dB(A)56 dB(A)
Refrigerant charge1.35 kg1.4 kg
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsTCLTHM16DFCTulip WiseTulip Next 18.3
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)16 kW218.42 kW✓3
Rated output 35 °C16 kW416 kW5
Rated output 55 °C15 kW416 kW✓5
Min. outdoor temperature-22 °C2–
Efficiency
SCOP (35 °C)4.83✓44.785
SCOP (55 °C)3.83✓43.75
Seasonal efficiency ηs 35 °C190 %✓4188 %5
Seasonal efficiency ηs 55 °C150 %✓4145 %5
Energy label 35 °CA+++4A+++5
Energy label 55 °CA+++4A++5
COP A7/W357.46✓14.61
COP A2/W354.46✓14.351
COP A-7/W352.713.57✓1
Noise
Outdoor unit sound power59 dB(A)456 dB(A)✓5
Refrigerant
RefrigerantR2901R2901
Refrigerant GWP3233
Refrigerant charge1.35 kg✓11.4 kg1
Electrical
Max. power input6.2 kW116 kW1
Connectivity & smart
SG ReadyYes1Yes1
Grants & market
ISDE grant (NL)4,375 €64,400 €✓7

Frequently asked questions

Which is better: the TCL THM16DFC or the Tulip Wise Tulip Next 18.3?

SCOP (35 °C): TCL THM16DFC 4.83, Tulip Wise Tulip Next 18.3 4.78. The TCL THM16DFC is better on 7 of 15 comparable points.

What is the SCOP (35 °C) of the TCL THM16DFC and the Tulip Wise Tulip Next 18.3?

TCL THM16DFC: 4.83. Tulip Wise Tulip Next 18.3: 4.78.

Which is better on COP A7/W35: the TCL THM16DFC or the Tulip Wise Tulip Next 18.3?

TCL THM16DFC: 7.46. Tulip Wise Tulip Next 18.3: 4.6.

Which is better on COP A-7/W35: the TCL THM16DFC or the Tulip Wise Tulip Next 18.3?

Tulip Wise Tulip Next 18.3: 3.57. TCL THM16DFC: 2.7.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  4. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  5. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
  6. ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026