Heat pumps · Compare

Shenling HPM-V120W/R3 vs AUX ACHP-H12/5R3HA-M

SCOP (35 °C): Shenling HPM-V120W/R3 4.9, AUX ACHP-H12/5R3HA-M 4.93. The AUX ACHP-H12/5R3HA-M is better on 7 of 14 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • Shenling HPM-V120W/R3
  • AUX ACHP-H12/5R3HA-M
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Shenling HPM-V120W/R3 62, AUX ACHP-H12/5R3HA-M 65; Efficiency: Shenling HPM-V120W/R3 50, AUX ACHP-H12/5R3HA-M 52; Noise: Shenling HPM-V120W/R3 41, AUX ACHP-H12/5R3HA-M 17; Refrigerant: Shenling HPM-V120W/R3 66, AUX ACHP-H12/5R3HA-M 40; Connectivity & smart: Shenling HPM-V120W/R3 50, AUX ACHP-H12/5R3HA-M 50

Biggest differences

FactHPM-V120W/R3ACHP-H12/5R3HA-M
Refrigerant GWP3675
Refrigerant charge1.4 kg1.7 kg
Outdoor unit sound power56 dB(A)63 dB(A)
COP A2/W354.524.83
SCOP (55 °C)3.783.55
Seasonal efficiency ηs 55 °C148 %139 %
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsShenlingHPM-V120W/R3AUXACHP-H12/5R3HA-M
Grants & market
Boiler Upgrade Scheme£7,500 – £9,000£7,500 – £9,000
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)12 kW212.2 kW✓3
Rated output 35 °C12 kW412.2 kW✓1
Rated output 55 °C12 kW412 kW1
Min. outdoor temperature-22 °C2–
Efficiency
SCOP (35 °C)4.944.93✓1
SCOP (55 °C)3.78✓43.551
Seasonal efficiency ηs 35 °C193 %4194 %✓1
Seasonal efficiency ηs 55 °C148 %✓4139 %1
Energy label 35 °CA+++4A+++3
Energy label 55 °CA++4A++3
COP A7/W354.7514.96✓1
COP A2/W354.5214.83✓1
COP A-7/W352.913.02✓1
Noise
Outdoor unit sound power56 dB(A)✓463 dB(A)1
Refrigerant
RefrigerantR2901R321
Refrigerant GWP3✓26753
Refrigerant charge1.4 kg✓11.7 kg1
Electrical
Max. power input5.8 kW115.3 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the Shenling HPM-V120W/R3 or the AUX ACHP-H12/5R3HA-M?

SCOP (35 °C): Shenling HPM-V120W/R3 4.9, AUX ACHP-H12/5R3HA-M 4.93. The AUX ACHP-H12/5R3HA-M is better on 7 of 14 comparable points.

What is the SCOP (35 °C) of the Shenling HPM-V120W/R3 and the AUX ACHP-H12/5R3HA-M?

Shenling HPM-V120W/R3: 4.9. AUX ACHP-H12/5R3HA-M: 4.93.

Which is better on refrigerant GWP: the Shenling HPM-V120W/R3 or the AUX ACHP-H12/5R3HA-M?

Shenling HPM-V120W/R3: 3. AUX ACHP-H12/5R3HA-M: 675.

Which is better on refrigerant charge: the Shenling HPM-V120W/R3 or the AUX ACHP-H12/5R3HA-M?

Shenling HPM-V120W/R3: 1.4 kg. AUX ACHP-H12/5R3HA-M: 1.7 kg.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 18 Oct 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026