DVI Energi DVI AW-290-4 vs Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001

SCOP (35 °C): DVI Energi DVI AW-290-4 4.7, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001 4.48. The DVI Energi DVI AW-290-4 is better on 8 of 14 comparable points.
Both models in detail
Who wins where
- DVI Energi DVI AW-290-4
- Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001
Biggest differences
| Fact | DVI AW-290-4 | Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001 |
|---|---|---|
| Refrigerant charge | 0.8 kg | 1.2 kg |
| Heating capacity (A7/W35) | 5.7 kW | 4 kW |
| COP A7/W35 | 4.41 | 5.62 |
| Rated output 55 °C | 4.27 kW | 3.77 kW |
| Rated output 35 °C | 4.6 kW | 4.08 kW |
| Seasonal efficiency ηs 55 °C | 143 % | 127 % |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | DVI EnergiDVI AW-290-4 | ViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001 |
|---|---|---|
| Grants & market | ||
| Boiler Upgrade Scheme | £7,500 – £9,000 | £7,500 – £9,000 |
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | 5.7 kW✓2 | 4 kW3 |
| Rated output 35 °C | 4.6 kW✓1 | 4.08 kW1 |
| Rated output 55 °C | 4.27 kW✓1 | 3.77 kW1 |
| Min. outdoor temperature | – | -20 °C3 |
| Efficiency | ||
| SCOP (35 °C) | 4.7✓1 | 4.481 |
| SCOP (55 °C) | 3.65✓1 | 3.251 |
| Seasonal efficiency ηs 35 °C | 185 %✓1 | 176 %1 |
| Seasonal efficiency ηs 55 °C | 143 %✓1 | 127 %1 |
| Energy label 35 °C | A+++2 | A+++3 |
| Energy label 55 °C | A++2 | A++3 |
| COP A7/W35 | 4.411 | 5.62✓1 |
| COP A2/W35 | – | 4.331 |
| COP A-7/W35 | 3.051 | 3.12✓1 |
| Noise | ||
| Outdoor unit sound power | 53 dB(A)1 | 51 dB(A)✓1 |
| Indoor unit sound power | 41 dB(A)1 | 40 dB(A)✓1 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 32 | 33 |
| Refrigerant charge | 0.8 kg✓1 | 1.2 kg1 |
| Electrical | ||
| Max. power input | 5 kW1 | 0.8 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
Frequently asked questions
Which is better: the DVI Energi DVI AW-290-4 or the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001?
SCOP (35 °C): DVI Energi DVI AW-290-4 4.7, Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001 4.48. The DVI Energi DVI AW-290-4 is better on 8 of 14 comparable points.
What is the SCOP (35 °C) of the DVI Energi DVI AW-290-4 and the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001?
DVI Energi DVI AW-290-4: 4.7. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001: 4.48.
Which is better on refrigerant charge: the DVI Energi DVI AW-290-4 or the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001?
DVI Energi DVI AW-290-4: 0.8 kg. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001: 1.2 kg.
Which is better on heating capacity (A7/W35): the DVI Energi DVI AW-290-4 or the Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001?
DVI Energi DVI AW-290-4: 5.7 kW. Viessmann Vitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001: 4 kW.
Related comparisons
- SolaXALT04-SF0vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001
- SolarEastBLN-004TC1vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.04-230-V001
- DVI EnergiDVI AW-290-7vsNew EnergyNE-F60HCR5INVMV2-PA
- DVI EnergiDVI AW-290-7vsRemehaConfida MB 400-4
- STIEBEL ELTRONLWZ 05.1 Plus H(K)WL 230vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
- STIEBEL ELTRONLWZ 05.1 Premium HKWL 230vsViessmannVitocal 150-A IDU-A AWMIW.A1.19-V052 / ODU 150-A AWMOF-151.A1.06-230-V001
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026