Air-to-water heat pumps (2026)
Take heat from the outside air and pass it to the heating water for underfloor heating or radiators, usually also for hot water. The most commonly installed type.
998 models in our database meet this; below the first 25 in order.
Criteria:
- Type (source): Air-to-water
- Sorted by: SCOP (35 °C) (highest first)
A ranking based on manufacturer and register data, not a test: we have not measured the units ourselves, and price, installation and service are not included. The source of every value is on the product page.
The ranking
Exinda XDASH06C3A
SCOP (35 °C) 6.32
- SCOP (35 °C) 6.32: the best of 998 models in this selection
- SCOP (55 °C) 3.89: no. 201 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
Heliotherm SNT70L-M-R-CC
SCOP (35 °C) 5.86
- SCOP (35 °C) 5.86: no. 2 of 998 models
- SCOP (55 °C) 4.3: no. 5 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
TCL THM8DFC
SCOP (35 °C) 5.85
- SCOP (55 °C) 4.38: joint best of 991 models
- SCOP (35 °C) 5.85: no. 3 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
Heliotherm SNT45L-M-R-CC
SCOP (35 °C) 5.84
- SCOP (35 °C) 5.84: no. 4 of 998 models
- SCOP (55 °C) 4.28: no. 8 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TCLrequest removal TCL THM4DFB
SCOP (35 °C) 5.8
- SCOP (55 °C) 4.38: joint best of 991 models
- SCOP (35 °C) 5.8: no. 5 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TEMPLARIrequest removal TEMPLARI Unità esterna KITA-SP-10, 1Ph, vers. MONOBLOCCO R-290
SCOP (35 °C) 5.75
- SCOP (35 °C) 5.75: no. 6 of 998 models
- SCOP (55 °C) 4.2: no. 12 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TEMPLARIrequest removal TEMPLARI UNITÀ ESTERNA KITA-LP PLUS-35, 3PH, VERS. MONOBLOCCO R-290
SCOP (35 °C) 5.71
- SCOP (35 °C) 5.71: no. 7 of 998 models
- SCOP (55 °C) 4.17: no. 16 of 991 models
- Weaker point: Outdoor unit sound power 61 dB(A): no. 791 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: iDMrequest removal iDM AERO ALM 10-24
SCOP (35 °C) 5.7
- SCOP (35 °C) 5.7: no. 8 of 998 models
- SCOP (55 °C) 4.2: no. 12 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: Kermirequest removal Kermi x-change dynamic pro M
SCOP (35 °C) 5.7
- SCOP (55 °C) 4.33: no. 4 of 991 models
- SCOP (35 °C) 5.7: no. 8 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: Kermirequest removal Kermi x-change dynamic pro S
SCOP (35 °C) 5.68
- SCOP (35 °C) 5.68: no. 10 of 998 models
- SCOP (55 °C) 4.23: no. 10 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TCLrequest removal TCL THM6DFB
SCOP (35 °C) 5.65
- SCOP (55 °C) 4.3: no. 5 of 991 models
- SCOP (35 °C) 5.65: no. 11 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
iDM AERO ALM 8-18
SCOP (35 °C) 5.62
- SCOP (35 °C) 5.62: no. 12 of 998 models
- SCOP (55 °C) 4.17: no. 16 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
M-TEC AHPA722
SCOP (35 °C) 5.62
- SCOP (55 °C) 4.35: no. 3 of 991 models
- SCOP (35 °C) 5.62: no. 12 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: REMKOrequest removal REMKO HTS 205
SCOP (35 °C) 5.62
- SCOP (35 °C) 5.62: no. 12 of 998 models
- SCOP (55 °C) 3.93: no. 149 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: REMKOrequest removal REMKO HTS 265
SCOP (35 °C) 5.62
- SCOP (35 °C) 5.62: no. 12 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
SOLARFOCUS vampair ECO 12/3
SCOP (35 °C) 5.62
- SCOP (35 °C) 5.62: no. 12 of 998 models
- SCOP (55 °C) 4.15: no. 22 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TEMPLARIrequest removal TEMPLARI Unità esterna KITA-SP-8, 1Ph, vers. MONOBLOCCO R-290
SCOP (35 °C) 5.61
- SCOP (35 °C) 5.61: no. 17 of 998 models
- SCOP (55 °C) 4.1: no. 42 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: Kermirequest removal Kermi x-change dynamic pro ac 10 AW E
SCOP (35 °C) 5.6
- SCOP (35 °C) 5.6: no. 18 of 998 models
- SCOP (55 °C) 3.88: no. 204 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: REMKOrequest removal REMKO HTS 95
SCOP (35 °C) 5.6
- SCOP (35 °C) 5.6: no. 18 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
ACOND Grandis R
SCOP (35 °C) 5.58
- SCOP (55 °C) 4.2: no. 12 of 991 models
- SCOP (35 °C) 5.58: no. 20 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: iDMrequest removal iDM AERO ALM 6-15
SCOP (35 °C) 5.58
- SCOP (35 °C) 5.58: no. 20 of 998 models
- SCOP (55 °C) 4.1: no. 42 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
SolarEast BLN-008TG1
SCOP (35 °C) 5.57
- SCOP (35 °C) 5.57: no. 22 of 998 models
- SCOP (55 °C) 4.07: no. 57 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: REMKOrequest removal REMKO HTS 135
SCOP (35 °C) 5.55
- SCOP (35 °C) 5.55: no. 23 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TEMPLARIrequest removal TEMPLARI UNITÀ ESTERNA KITA-LP PLUS-40, 3PH, VERS. MONOBLOCCO R-290
SCOP (35 °C) 5.55
- SCOP (35 °C) 5.55: no. 23 of 998 models
- SCOP (55 °C) 4.12: no. 29 of 991 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.

Image: TEMPLARIrequest removal TEMPLARI Unità esterna KITA-LP-26, 3Ph, vers. MONOBLOCCO R-290
SCOP (35 °C) 5.51
- SCOP (35 °C) 5.51: no. 25 of 998 models
- SCOP (55 °C) 4.15: no. 22 of 991 models
- Weaker point: Outdoor unit sound power 61 dB(A): no. 791 of 998 models
Choose this model if you have underfloor heating and want to use as little electricity as possible.
All figures at a glance
| # | Model1,2 | SCOP (35 °C) | Rated output 35 °C | SCOP (55 °C) | Outdoor unit sound power | Refrigerant |
|---|---|---|---|---|---|---|
| 1 | Exinda XDASH06C3A | 6.32 | 6.7 kW | 3.89 | 53 dB(A) | R290 |
| 2 | Heliotherm SNT70L-M-R-CC | 5.86 | 70 kW | 4.3 | 56 dB(A) | R290 |
| 3 | TCL THM8DFC | 5.85 | 8 kW | 4.38 | 53 dB(A) | R290 |
| 4 | Heliotherm SNT45L-M-R-CC | 5.84 | 45 kW | 4.28 | 53 dB(A) | R290 |
| 5 | TCL THM4DFB | 5.8 | 5 kW | 4.38 | 51 dB(A) | R290 |
| 6 | TEMPLARI Unità esterna KITA-SP-10, 1Ph, vers. MONOBLOCCO R-290 | 5.75 | 8.34 kW | 4.2 | 50 dB(A) | R290 |
| 7 | TEMPLARI UNITÀ ESTERNA KITA-LP PLUS-35, 3PH, VERS. MONOBLOCCO R-290 | 5.71 | 29 kW | 4.17 | 61 dB(A) | R290 |
| 8 | iDM AERO ALM 10-24 | 5.7 | 21 kW | 4.2 | 56 dB(A) | R290 |
| 9 | Kermi x-change dynamic pro M | 5.7 | 10 kW | 4.33 | 47 dB(A) | R290 |
| 10 | Kermi x-change dynamic pro S | 5.68 | 7 kW | 4.23 | 45 dB(A) | R290 |
| 11 | TCL THM6DFB | 5.65 | 7 kW | 4.3 | 53 dB(A) | R290 |
| 12 | iDM AERO ALM 8-18 | 5.62 | 17 kW | 4.17 | 53 dB(A) | R290 |
| 13 | M-TEC AHPA722 | 5.62 | 18.86 kW | 4.35 | 52 dB(A) | R290 |
| 14 | REMKO HTS 205 | 5.62 | 10 kW | 3.93 | 58 dB(A) | R32 |
| 15 | REMKO HTS 265 | 5.62 | 13 kW | 3.85 | 58 dB(A) | R32 |
| 16 | SOLARFOCUS vampair ECO 12/3 | 5.62 | 10 kW | 4.15 | 50 dB(A) | R290 |
| 17 | TEMPLARI Unità esterna KITA-SP-8, 1Ph, vers. MONOBLOCCO R-290 | 5.61 | 6.53 kW | 4.1 | 50 dB(A) | R290 |
| 18 | Kermi x-change dynamic pro ac 10 AW E | 5.6 | 11 kW | 3.88 | 51 dB(A) | R32 |
| 19 | REMKO HTS 95 | 5.6 | 5 kW | 3.85 | 58 dB(A) | R32 |
| 20 | ACOND Grandis R | 5.58 | 10 kW | 4.2 | 48 dB(A) | R290 |
| 21 | iDM AERO ALM 6-15 | 5.58 | 12 kW | 4.1 | 50 dB(A) | R290 |
| 22 | SolarEast BLN-008TG1 | 5.57 | 8.01 kW | 4.07 | 50 dB(A) | R290 |
| 23 | REMKO HTS 135 | 5.55 | 7 kW | 3.83 | 58 dB(A) | R32 |
| 24 | TEMPLARI UNITÀ ESTERNA KITA-LP PLUS-40, 3PH, VERS. MONOBLOCCO R-290 | 5.55 | 33.25 kW | 4.12 | 50.1 dB(A) | R290 |
| 25 | TEMPLARI Unità esterna KITA-LP-26, 3Ph, vers. MONOBLOCCO R-290 | 5.51 | 22.02 kW | 4.15 | 61 dB(A) | R290 |
How this ranking is made
This selection is put together automatically from the 998 models in our database that meet the criteria above. We only include models whose figures for the ranking are known: without those values a model cannot be compared fairly, so it drops out. The list is recalculated with every data update, so the order can change as soon as manufacturers or registers publish new values.
The order follows a single feature: SCOP (35 °C) (highest first). Where values are equal, the alphabetical order of brand and model decides. The other features are shown as extra columns in the table so you can see how a model does on other points; a model at the top for this one feature can be weaker elsewhere.
The reasoning for each place is derived automatically from the same data. We name the features on which the model is in the best quarter of this selection, functions that not every model has, and a weaker point if the model falls in the bottom quarter on it. The line ‘Choose this model if …’ links the most heavily weighted strength to a situation where it matters. This is not a test and not personal advice: the installation, your home and the price also decide what works best for you.
The values come from EPREL, Keymark and manufacturers; the product page shows the source of every value. How we collect and check the data →
More selections
- Quietest 4–6 kW air-to-water heat pumps
- Most efficient 4–6 kW air-to-water heat pumps
- Quietest 6–8 kW air-to-water heat pumps
- Most efficient 6–8 kW air-to-water heat pumps
- Quietest 8–10 kW air-to-water heat pumps
- Most efficient 8–10 kW air-to-water heat pumps
- Quietest 10–14 kW air-to-water heat pumps
- Most efficient 10–14 kW air-to-water heat pumps
- Best air source heat pumps
- Best 4–6 kW air source heat pumps
- Best 6–8 kW air source heat pumps
- Best 8–12 kW air source heat pumps
- Best 12–16 kW air source heat pumps
- Quietest air source heat pumps
- Heat pumps with R290 (propane)
- Most efficient heat pumps for radiators (55 °C)
- Ground-source heat pumps (brine-to-water)
- Water-to-water heat pumps (groundwater)
- Best hybrid heat pumps (with a gas boiler)
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026