Heat pumps · Compare

STIEBEL ELTRON LWZ 8 CS Trend vs TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290

SCOP (35 °C): STIEBEL ELTRON LWZ 8 CS Trend 4.14, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 5.32. The TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 is better on 12 of 15 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • STIEBEL ELTRON LWZ 8 CS Trend
  • TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: STIEBEL ELTRON LWZ 8 CS Trend 26, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 55; Efficiency: STIEBEL ELTRON LWZ 8 CS Trend 10, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 62; Noise: STIEBEL ELTRON LWZ 8 CS Trend 47, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 47; Refrigerant: STIEBEL ELTRON LWZ 8 CS Trend 15, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 68; Connectivity & smart: STIEBEL ELTRON LWZ 8 CS Trend 50, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 50

Biggest differences

FactLWZ 8 CS TrendUNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290
Refrigerant GWP2,0883
Heating capacity (A7/W35)4.4 kW12.09 kW
Refrigerant charge2.95 kg1.35 kg
Rated output 55 °C7 kW9.32 kW
Seasonal efficiency ηs 35 °C163 %210 %
SCOP (35 °C)4.145.32
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsSTIEBEL ELTRONLWZ 8 CS TrendTEMPLARIUNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)4.4 kW212.09 kW✓3
Rated output 35 °C10 kW✓19.97 kW1
Rated output 55 °C7 kW19.32 kW✓1
Min. outdoor temperature-20 °C2-22 °C✓3
Efficiency
SCOP (35 °C)4.1415.32✓1
SCOP (55 °C)3.2813.8✓1
Seasonal efficiency ηs 35 °C163 %1210 %✓1
Seasonal efficiency ηs 55 °C128 %1149 %✓1
Energy label 35 °CA++2A+++3
Energy label 55 °CA++2A++3
COP A7/W354.7414.9✓1
COP A2/W353.7414.23✓1
COP A-7/W352.6113.11✓1
Noise
Outdoor unit sound power55 dB(A)155 dB(A)1
Indoor unit sound power50 dB(A)1–
Refrigerant
RefrigerantR410A1R2901
Refrigerant GWP2,08823✓3
Refrigerant charge2.95 kg11.35 kg✓1
Electrical
Max. power input5.3 kW14.02 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the STIEBEL ELTRON LWZ 8 CS Trend or the TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290?

SCOP (35 °C): STIEBEL ELTRON LWZ 8 CS Trend 4.14, TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 5.32. The TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290 is better on 12 of 15 comparable points.

What is the SCOP (35 °C) of the STIEBEL ELTRON LWZ 8 CS Trend and the TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290?

STIEBEL ELTRON LWZ 8 CS Trend: 4.14. TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290: 5.32.

Which is better on refrigerant GWP: the STIEBEL ELTRON LWZ 8 CS Trend or the TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290?

TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290: 3. STIEBEL ELTRON LWZ 8 CS Trend: 2,088.

Which is better on heating capacity (A7/W35): the STIEBEL ELTRON LWZ 8 CS Trend or the TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290?

TEMPLARI UNITÀ ESTERNA KITA-HRP-12, 1PH, VERS. MONOBLOCCO R-290: 12.09 kW. STIEBEL ELTRON LWZ 8 CS Trend: 4.4 kW.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026