Heat pumps · 115 models

Quietest 4–6 kW air-to-water heat pumps (2026)

115 models in our database meet this; below the first 25 in order.

Criteria:

  • Type (source): Air-to-water
  • Rated output 35 °C from 4 up to 6 kW
  • Sorted by: Outdoor unit sound power (lowest first)

Air-to-water heat pumps only: ground-source and water-to-water heat pumps reach a higher SCOP thanks to their warmer source, so they cannot be compared fairly with air-to-water units. They have their own selections.

A ranking based on manufacturer and register data, not a test: we have not measured the units ourselves, and price, installation and service are not included. The source of every value is on the product page.

The ranking

  1. STIEBEL ELTRON WPL 09 ICS classic

    Outdoor unit sound power 32 dB(A)

    • Outdoor unit sound power 32 dB(A): joint best of 115 models
    • Weaker point: SCOP (35 °C) 4.53: no. 92 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  2. STIEBEL ELTRON WPL 09 IKCS classic

    Outdoor unit sound power 32 dB(A)

    • Outdoor unit sound power 32 dB(A): joint best of 115 models
    • Weaker point: SCOP (35 °C) 4.45: no. 98 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  3. Tecalor TTL 4.5 ICS

    Outdoor unit sound power 32 dB(A)

    • Outdoor unit sound power 32 dB(A): joint best of 115 models
    • Weaker point: SCOP (35 °C) 4.53: no. 92 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  4. Tecalor TTL 4.5 IKCS

    Outdoor unit sound power 32 dB(A)

    • Outdoor unit sound power 32 dB(A): joint best of 115 models
    • Weaker point: SCOP (35 °C) 4.45: no. 98 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  5. Bosch Compress 7000i AW CS7000iAW 7 IRB-S

    Outdoor unit sound power 36 dB(A)

    • Outdoor unit sound power 36 dB(A): no. 5 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  6. Bosch Compress 7000i AW CS7000iAW 7 IRMB-S

    Outdoor unit sound power 36 dB(A)

    • Outdoor unit sound power 36 dB(A): no. 5 of 115 models
    • Weaker point: SCOP (35 °C) 4.41: no. 101 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  7. Bosch Compress 5800i AW CS5800iAW 4 OR210 MP-S

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models
    • Weaker point: SCOP (35 °C) 4.14: no. 113 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  8. Bosch Compress 5800i AW CS5800iAW 4 ORE-S

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  9. Bosch Compress 5800i AW CS5800iAW 4 ORM-S

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  10. Bosch Compress 5800i AW CS5800iAW 4 ORMB-S

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  11. Bosch Compress CS5800iAW 4 ORMB-S (AW 4 OR-S + CS5800iAW 12 MB)

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  12. Bosch Compress CS6800iAW 4 ORMB-S (AW 4 OR-S + CS6800iAW 12 MB)

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  13. Bosch CSH5800iAW 4

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models
    • Weaker point: SCOP (35 °C) 4.34: no. 104 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  14. Buderus HC HYC20 IT-4

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models
    • Weaker point: SCOP (35 °C) 4.34: no. 104 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  15. Buderus Logaplus M WLW176i-4 AR E (Logatherm WLW-4 MB AR + WLW176i-12 E)

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  16. Buderus Logaplus M WLW176i-4 AR TP70 (Logatherm WLW-4 MB AR + WLW176i-12 TP70)

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  17. Buderus Logatherm WLW176i-4 AR E

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  18. Buderus Logatherm WLW176i-4 AR T180

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  19. Buderus Logatherm WLW176i-4 AR TP70

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  20. Buderus M WLW186i-4 AR E (W)

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  21. Buderus M WLW186i-4 AR T180 W

    Outdoor unit sound power 40 dB(A)

    • Outdoor unit sound power 40 dB(A): no. 7 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  22. Cosmogas SYLENTIA 8M

    Outdoor unit sound power 44 dB(A)

    • Outdoor unit sound power 44 dB(A): no. 22 of 115 models
    • Weaker point: SCOP (35 °C) 4.53: no. 92 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  23. Tecalor THZ 05.1 IB(C) comfort

    Outdoor unit sound power 44 dB(A)

    • Outdoor unit sound power 44 dB(A): no. 22 of 115 models
    • Weaker point: SCOP (35 °C) 4.28: no. 108 of 115 models

    Choose this model if the outdoor unit will sit close to neighbours, a patio or a bedroom.

  24. ACOND Grandis N

    Outdoor unit sound power 46 dB(A)

    • SCOP (35 °C) 5.38: no. 4 of 115 models

    Choose this model if you have underfloor heating and want to use as little electricity as possible.

  25. Clivet WiSAN-PMP 1 S 2.1

    Outdoor unit sound power 46 dB(A)

    • SCOP (35 °C) 5.23: no. 8 of 115 models

    Choose this model if you have underfloor heating and want to use as little electricity as possible.

All figures at a glance

#Model1,2,3Outdoor unit sound powerRated output 35 °CSCOP (35 °C)Refrigerant
1STIEBEL ELTRON WPL 09 ICS classic32 dB(A)5 kW4.53R410A
2STIEBEL ELTRON WPL 09 IKCS classic32 dB(A)5 kW4.45R410A
3Tecalor TTL 4.5 ICS32 dB(A)5 kW4.53R410A
4Tecalor TTL 4.5 IKCS32 dB(A)5 kW4.45R410A
5Bosch Compress 7000i AW CS7000iAW 7 IRB-S36 dB(A)5.18 kW4.68R410A
6Bosch Compress 7000i AW CS7000iAW 7 IRMB-S36 dB(A)5.17 kW4.41R410A
7Bosch Compress 5800i AW CS5800iAW 4 OR210 MP-S40 dB(A)4.4 kW4.14R290
8Bosch Compress 5800i AW CS5800iAW 4 ORE-S40 dB(A)4.4 kW4.58R290
9Bosch Compress 5800i AW CS5800iAW 4 ORM-S40 dB(A)4.4 kW4.55R290
10Bosch Compress 5800i AW CS5800iAW 4 ORMB-S40 dB(A)4.4 kW4.55R290
11Bosch Compress CS5800iAW 4 ORMB-S (AW 4 OR-S + CS5800iAW 12 MB)40 dB(A)4.4 kW4.55R290
12Bosch Compress CS6800iAW 4 ORMB-S (AW 4 OR-S + CS6800iAW 12 MB)40 dB(A)4.4 kW4.55R290
13Bosch CSH5800iAW 440 dB(A)4.4 kW4.34R290
14Buderus HC HYC20 IT-440 dB(A)4.4 kW4.34R290
15Buderus Logaplus M WLW176i-4 AR E (Logatherm WLW-4 MB AR + WLW176i-12 E)40 dB(A)4.4 kW4.58R290
16Buderus Logaplus M WLW176i-4 AR TP70 (Logatherm WLW-4 MB AR + WLW176i-12 TP70)40 dB(A)4.4 kW4.55R290
17Buderus Logatherm WLW176i-4 AR E40 dB(A)4.4 kW4.58R290
18Buderus Logatherm WLW176i-4 AR T18040 dB(A)4.4 kW4.55R290
19Buderus Logatherm WLW176i-4 AR TP7040 dB(A)4.4 kW4.55R290
20Buderus M WLW186i-4 AR E (W)40 dB(A)4.4 kW4.58R290
21Buderus M WLW186i-4 AR T180 W40 dB(A)4.4 kW4.55R290
22Cosmogas SYLENTIA 8M44 dB(A)5 kW4.53R290
23Tecalor THZ 05.1 IB(C) comfort44 dB(A)5.47 kW4.28R290
24ACOND Grandis N46 dB(A)4 kW5.38R290
25Clivet WiSAN-PMP 1 S 2.146 dB(A)5 kW5.23R290

Compare all models →

How this ranking is made

This selection is put together automatically from the 115 models in our database that meet the criteria above. We only include models whose figures for the ranking are known: without those values a model cannot be compared fairly, so it drops out. The list is recalculated with every data update, so the order can change as soon as manufacturers or registers publish new values.

The order follows a single feature: Outdoor unit sound power (lowest first). Where values are equal, the alphabetical order of brand and model decides. The other features are shown as extra columns in the table so you can see how a model does on other points; a model at the top for this one feature can be weaker elsewhere.

The reasoning for each place is derived automatically from the same data. We name the features on which the model is in the best quarter of this selection, functions that not every model has, and a weaker point if the model falls in the bottom quarter on it. The line ‘Choose this model if …’ links the most heavily weighted strength to a situation where it matters. This is not a test and not personal advice: the installation, your home and the price also decide what works best for you.

The values come from EPREL, Keymark and manufacturers; the product page shows the source of every value. How we collect and check the data →

More selections

Sources

  1. European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed Oct 15, 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026
  3. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Sep 27, 2026