Most efficient heat pumps for radiators (55 °C, 2026)
1343 models in our database meet this; below the first 25 in order.
Criteria:
- Sorted by: SCOP (55 °C) (highest first)
A ranking based on manufacturer and register data, not a test: we have not measured the units ourselves, and price, installation and service are not included. The source of every value is on the product page.
The ranking
iDM iPump T 2-8
SCOP (55 °C) 6.35
- SCOP (55 °C) 6.35: the best of 1,343 models in this selection
- SCOP (35 °C) 7.93: no. 3 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
Hoval UltraSource T comfort (13)
SCOP (55 °C) 6.33
- SCOP (55 °C) 6.33: no. 2 of 1,343 models
- SCOP (35 °C) 7.92: no. 5 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
Hoval UltraSource T comfort (8)
SCOP (55 °C) 6.33
- SCOP (55 °C) 6.33: no. 2 of 1,343 models
- SCOP (35 °C) 7.92: no. 5 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: ELCOrequest removal ELCO AQUATOP S06
SCOP (55 °C) 6
- SCOP (55 °C) 6: no. 4 of 1,343 models
- SCOP (35 °C) 6.28: no. 87 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Ratiothermrequest removal Ratiotherm WP Max-Cube pF26
SCOP (55 °C) 5.9
- SCOP (55 °C) 5.9: no. 5 of 1,343 models
- SCOP (35 °C) 6.31: no. 83 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
Hoval UltraSource T comfort (17)
SCOP (55 °C) 5.85
- SCOP (35 °C) 7.96: no. 2 of 1,350 models
- SCOP (55 °C) 5.85: no. 6 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
iDM TERRA SWM 6-17
SCOP (55 °C) 5.85
- SCOP (35 °C) 7.98: the best of 1,350 models in this selection
- SCOP (55 °C) 5.85: no. 6 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
CTC EcoPart 7060
SCOP (55 °C) 5.73
- SCOP (55 °C) 5.73: no. 8 of 1,343 models
- SCOP (35 °C) 7.81: no. 14 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: iDMrequest removal iDM TERRA SW 20 Twin
SCOP (55 °C) 5.73
- SCOP (35 °C) 7.92: no. 5 of 1,350 models
- SCOP (55 °C) 5.73: no. 8 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
Waterkotte Industrial Line 8060.7 (W/W)
SCOP (55 °C) 5.73
- SCOP (55 °C) 5.73: no. 8 of 1,343 models
- SCOP (35 °C) 7.81: no. 14 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
M-TEC VHPA27 W
SCOP (55 °C) 5.65
- SCOP (35 °C) 7.93: no. 3 of 1,350 models
- SCOP (55 °C) 5.65: no. 11 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
M-TEC VHPA214 W
SCOP (55 °C) 5.64
- SCOP (35 °C) 7.86: no. 11 of 1,350 models
- SCOP (55 °C) 5.64: no. 12 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: NIBErequest removal NIBE S1156-8
SCOP (55 °C) 5.63
- SCOP (35 °C) 7.87: no. 9 of 1,350 models
- SCOP (55 °C) 5.63: no. 13 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
M-TEC VHPA221 W
SCOP (55 °C) 5.62
- SCOP (35 °C) 7.86: no. 11 of 1,350 models
- SCOP (55 °C) 5.62: no. 14 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: NIBErequest removal NIBE S1156-8 (W/W)
SCOP (55 °C) 5.62
- SCOP (35 °C) 7.87: no. 9 of 1,350 models
- SCOP (55 °C) 5.62: no. 14 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
M-TEC WHPA412
SCOP (55 °C) 5.61
- SCOP (35 °C) 7.78: no. 16 of 1,350 models
- SCOP (55 °C) 5.61: no. 16 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
M-TEC VHPA228 W
SCOP (55 °C) 5.6
- SCOP (35 °C) 7.82: no. 13 of 1,350 models
- SCOP (55 °C) 5.6: no. 17 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: iDMrequest removal iDM TERRA SW 35 Twin
SCOP (55 °C) 5.58
- SCOP (55 °C) 5.58: no. 18 of 1,343 models
- SCOP (35 °C) 7.45: no. 26 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
NIBE F1153-6 PC
SCOP (55 °C) 5.55
- SCOP (55 °C) 5.55: no. 19 of 1,343 models
- SCOP (35 °C) 6.95: no. 51 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Ochsnerrequest removal Ochsner AQUA FOX 312 HPLA S1
SCOP (55 °C) 5.53
- SCOP (55 °C) 5.53: no. 20 of 1,343 models
- SCOP (35 °C) 7.51: no. 25 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Boschrequest removal Bosch Compress 7800i LW CS7800i LW 16 (+F)
SCOP (55 °C) 5.51
- SCOP (55 °C) 5.51: no. 21 of 1,343 models
- SCOP (35 °C) 7.43: no. 27 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Buderusrequest removal Buderus WSW196i.2-16 (+W) / 186-16
SCOP (55 °C) 5.51
- SCOP (55 °C) 5.51: no. 21 of 1,343 models
- SCOP (35 °C) 7.43: no. 27 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Boschrequest removal Bosch Compress CS7800i LW 16 M/MB/F
SCOP (55 °C) 5.5
- SCOP (55 °C) 5.5: no. 23 of 1,343 models
- SCOP (35 °C) 7.43: no. 27 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: iDMrequest removal iDM TERRA SW 26 Twin
SCOP (55 °C) 5.48
- SCOP (55 °C) 5.48: no. 24 of 1,343 models
- SCOP (35 °C) 7.4: no. 30 of 1,350 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.

Image: Kronotermrequest removal Kronoterm ETERA M-1 HT / HK UF E
SCOP (55 °C) 5.47
- SCOP (35 °C) 7.72: no. 17 of 1,350 models
- SCOP (55 °C) 5.47: no. 25 of 1,343 models
Choose this model if you are keeping (some) radiators and the heat pump has to run at a higher flow temperature.
All figures at a glance
| # | Model1,2 | SCOP (55 °C) | Type (source) | Rated output 55 °C | SCOP (35 °C) | Refrigerant |
|---|---|---|---|---|---|---|
| 1 | iDM iPump T 2-8 | 6.35 | Water-to-water | 10.4 kW | 7.93 | R410A |
| 2 | Hoval UltraSource T comfort (13) | 6.33 | Water-to-water | 10.4 kW | 7.92 | R410A |
| 3 | Hoval UltraSource T comfort (8) | 6.33 | Water-to-water | 10.4 kW | 7.92 | R410A |
| 4 | ELCO AQUATOP S06 | 6 | Ground source | 6.07 kW | 6.28 | R410A |
| 5 | Ratiotherm WP Max-Cube pF26 | 5.9 | Water-to-water | 30 kW | 6.31 | R290 |
| 6 | Hoval UltraSource T comfort (17) | 5.85 | Water-to-water | 25.7 kW | 7.96 | R410A |
| 7 | iDM TERRA SWM 6-17 | 5.85 | Water-to-water | 25.7 kW | 7.98 | R410A |
| 8 | CTC EcoPart 7060 | 5.73 | Ground source | 54.5 kW | 7.81 | R290 |
| 9 | iDM TERRA SW 20 Twin | 5.73 | Water-to-water | 24.7 kW | 7.92 | R410A |
| 10 | Waterkotte Industrial Line 8060.7 (W/W) | 5.73 | Water-to-water | 54.5 kW | 7.81 | R290 |
| 11 | M-TEC VHPA27 W | 5.65 | Water-to-water | 8.21 kW | 7.93 | R290 |
| 12 | M-TEC VHPA214 W | 5.64 | Water-to-water | 16.19 kW | 7.86 | R290 |
| 13 | NIBE S1156-8 | 5.63 | Ground source | 10 kW | 7.87 | R454B |
| 14 | M-TEC VHPA221 W | 5.62 | Water-to-water | 24.28 kW | 7.86 | R290 |
| 15 | NIBE S1156-8 (W/W) | 5.62 | Water-to-water | 10 kW | 7.87 | R454B |
| 16 | M-TEC WHPA412 | 5.61 | Water-to-water | 13.75 kW | 7.78 | R290 |
| 17 | M-TEC VHPA228 W | 5.6 | Water-to-water | 31.99 kW | 7.82 | R290 |
| 18 | iDM TERRA SW 35 Twin | 5.58 | Water-to-water | 43.6 kW | 7.45 | R410A |
| 19 | NIBE F1153-6 PC | 5.55 | Ground source | 7 kW | 6.95 | R407C |
| 20 | Ochsner AQUA FOX 312 HPLA S1 | 5.53 | Water-to-water | 14 kW | 7.51 | R452B |
| 21 | Bosch Compress 7800i LW CS7800i LW 16 (+F) | 5.51 | Ground source | 17.37 kW | 7.43 | R410A |
| 22 | Buderus WSW196i.2-16 (+W) / 186-16 | 5.51 | Ground source | 17.37 kW | 7.43 | R410A |
| 23 | Bosch Compress CS7800i LW 16 M/MB/F | 5.5 | Water-to-water | 17.36 kW | 7.43 | R410A |
| 24 | iDM TERRA SW 26 Twin | 5.48 | Water-to-water | 31.2 kW | 7.4 | R410A |
| 25 | Kronoterm ETERA M-1 HT / HK UF E | 5.47 | Ground source | 12.1 kW | 7.72 | R452B |
How this ranking is made
This selection is put together automatically from the 1,343 models in our database that meet the criteria above. We only include models whose figures for the ranking are known: without those values a model cannot be compared fairly, so it drops out. The list is recalculated with every data update, so the order can change as soon as manufacturers or registers publish new values.
The order follows a single feature: SCOP (55 °C) (highest first). Where values are equal, the alphabetical order of brand and model decides. The other features are shown as extra columns in the table so you can see how a model does on other points; a model at the top for this one feature can be weaker elsewhere.
The reasoning for each place is derived automatically from the same data. We name the features on which the model is in the best quarter of this selection, functions that not every model has, and a weaker point if the model falls in the bottom quarter on it. The line ‘Choose this model if …’ links the most heavily weighted strength to a situation where it matters. This is not a test and not personal advice: the installation, your home and the price also decide what works best for you.
The values come from EPREL, Keymark and manufacturers; the product page shows the source of every value. How we collect and check the data →
More selections
- Quietest 4–6 kW air-to-water heat pumps
- Most efficient 4–6 kW air-to-water heat pumps
- Quietest 6–8 kW air-to-water heat pumps
- Most efficient 6–8 kW air-to-water heat pumps
- Quietest 8–10 kW air-to-water heat pumps
- Most efficient 8–10 kW air-to-water heat pumps
- Quietest 10–14 kW air-to-water heat pumps
- Most efficient 10–14 kW air-to-water heat pumps
- Best air source heat pumps
- Best 4–6 kW air source heat pumps
- Best 6–8 kW air source heat pumps
- Best 8–12 kW air source heat pumps
- Best 12–16 kW air source heat pumps
- Quietest air source heat pumps
- Heat pumps with R290 (propane)
- Air-to-water heat pumps
- Ground-source heat pumps (brine-to-water)
- Water-to-water heat pumps (groundwater)
- Best hybrid heat pumps (with a gas boiler)
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed Oct 18, 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed Sep 29, 2026