M-TEC AHPA618 vs Tulip Wise Tulip Next 18.3

SCOP (35 °C): M-TEC AHPA618 5.15, Tulip Wise Tulip Next 18.3 4.78. The M-TEC AHPA618 is better on 7 of 14 comparable points.
Last updated: + Add a model
Both models in detail
Who wins where
- M-TEC AHPA618
- Tulip Wise Tulip Next 18.3
Biggest differences
| Fact | AHPA618 | Tulip Next 18.3 |
|---|---|---|
| Refrigerant charge | 3.1 kg | 1.4 kg |
| COP A2/W35 | 5.06 | 4.35 |
| COP A-7/W35 | 3.18 | 3.57 |
| COP A7/W35 | 5.12 | 4.6 |
| Seasonal efficiency ηs 35 °C | 203 % | 188 % |
| SCOP (35 °C) | 5.15 | 4.78 |
Score per area = position (0–100) relative to all 1350 models in this category; higher is better.
| Technical specifications | M-TECAHPA618 | Tulip WiseTulip Next 18.3 |
|---|---|---|
| General | ||
| Type (source) | Air-to-water1 | Air-to-water1 |
| Performance | ||
| Heating capacity (A7/W35) | – | 18.42 kW2 |
| Rated output 35 °C | 16 kW1 | 16 kW3 |
| Rated output 55 °C | 15.4 kW1 | 16 kW✓3 |
| Efficiency | ||
| SCOP (35 °C) | 5.15✓1 | 4.783 |
| SCOP (55 °C) | 3.93✓1 | 3.73 |
| Seasonal efficiency ηs 35 °C | 203 %✓1 | 188 %3 |
| Seasonal efficiency ηs 55 °C | 154 %✓1 | 145 %3 |
| Energy label 35 °C | – | A+++3 |
| Energy label 55 °C | – | A++3 |
| COP A7/W35 | 5.12✓1 | 4.61 |
| COP A2/W35 | 5.06✓1 | 4.351 |
| COP A-7/W35 | 3.181 | 3.57✓1 |
| Noise | ||
| Outdoor unit sound power | 53.7 dB(A)✓1 | 56 dB(A)3 |
| Refrigerant | ||
| Refrigerant | R2901 | R2901 |
| Refrigerant GWP | 34 | 32 |
| Refrigerant charge | 3.1 kg1 | 1.4 kg✓1 |
| Electrical | ||
| Max. power input | 6.9 kW1 | 16 kW1 |
| Connectivity & smart | ||
| SG Ready | Yes1 | Yes1 |
| Grants & market | ||
| ISDE grant (NL) | 4,375 €4 | 4,400 €✓5 |
Frequently asked questions
Which is better: the M-TEC AHPA618 or the Tulip Wise Tulip Next 18.3?
SCOP (35 °C): M-TEC AHPA618 5.15, Tulip Wise Tulip Next 18.3 4.78. The M-TEC AHPA618 is better on 7 of 14 comparable points.
What is the SCOP (35 °C) of the M-TEC AHPA618 and the Tulip Wise Tulip Next 18.3?
M-TEC AHPA618: 5.15. Tulip Wise Tulip Next 18.3: 4.78.
Which is better on refrigerant charge: the M-TEC AHPA618 or the Tulip Wise Tulip Next 18.3?
Tulip Wise Tulip Next 18.3: 1.4 kg. M-TEC AHPA618: 3.1 kg.
Which is better on COP A2/W35: the M-TEC AHPA618 or the Tulip Wise Tulip Next 18.3?
M-TEC AHPA618: 5.06. Tulip Wise Tulip Next 18.3: 4.35.
Related comparisons
How we collect and check this data →
Sources
- List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- European Product Registry for Energy Labelling (EPREL) – heat pumps — Europese Commissie · accessed 15 Oct 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 25 Oct 2026
- ISDE heat pump notification code list — Rijksdienst voor Ondernemend Nederland (RVO) · accessed 28 Sept 2026