Heat pumps · Compare

Inventor MX290-40T vs AUX ACHM-H40/5R2A

SCOP (35 °C): Inventor MX290-40T 4.2, AUX ACHM-H40/5R2A 4.7. The AUX ACHM-H40/5R2A is better on 9 of 14 comparable points.

Who wins where

  • Inventor MX290-40T
  • AUX ACHM-H40/5R2A
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: Inventor MX290-40T 96, AUX ACHM-H40/5R2A 96; Efficiency: Inventor MX290-40T 8, AUX ACHM-H40/5R2A 57; Noise: Inventor MX290-40T 1, AUX ACHM-H40/5R2A 39; Refrigerant: Inventor MX290-40T 49, AUX ACHM-H40/5R2A 49; Connectivity & smart: Inventor MX290-40T 50, AUX ACHM-H40/5R2A 50

Biggest differences

FactMX290-40TACHM-H40/5R2A
COP A7/W353.76.84
COP A2/W353.154.42
Outdoor unit sound power76 dB(A)57 dB(A)
Seasonal efficiency ηs 55 °C132.5 %155 %
SCOP (55 °C)3.393.95
Rated output 55 °C39 kW34 kW
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specifications InventorMX290-40T AUXACHM-H40/5R2A
General
Type (source) Air-to-water 1 Air-to-water 1
Performance
Heating capacity (A7/W35) 39 kW 2 40 kW ✓ 3
Rated output 35 °C 39 kW 1 39 kW 1
Rated output 55 °C 39 kW ✓ 1 34 kW 1
Min. outdoor temperature -22 °C 2 –
Efficiency
SCOP (35 °C) 4.2 1 4.7 ✓ 1
SCOP (55 °C) 3.39 1 3.95 ✓ 1
Seasonal efficiency ηs 35 °C 165.1 % 1 185 % ✓ 1
Seasonal efficiency ηs 55 °C 132.5 % 1 155 % ✓ 1
Energy label 35 °C A, , 2 A, , , 3
Energy label 55 °C A, , 2 A, , , 3
COP A7/W35 3.7 1 6.84 ✓ 1
COP A2/W35 3.15 1 4.42 ✓ 1
COP A-7/W35 2.5 1 2.71 ✓ 1
Noise
Outdoor unit sound power 76 dB(A) 1 57 dB(A) ✓ 1
Refrigerant
Refrigerant R290 1 R290 1
Refrigerant GWP 3 2 3 3
Refrigerant charge 2.9 kg 1 2.9 kg 1
Electrical
Max. power input 15.96 kW 1 21 kW 1
Connectivity & smart
SG Ready Yes 1 Yes 1

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026