Heat pumps · Compare

ELCO AEROTOP SPK10 vs Viessmann Vitocal 200-S AWB-M-E-AC 201.E08

SCOP (35 °C): ELCO AEROTOP SPK10 4.86, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 4.9. The Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 is better on 8 of 16 comparable points.

Last updated: + Add a model

Both models in detail

Who wins where

  • ELCO AEROTOP SPK10
  • Viessmann Vitocal 200-S AWB-M-E-AC 201.E08
PerformanceEfficiencyNoiseRefrigerantConnectivity & smart
Performance: ELCO AEROTOP SPK10 33, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 27; Efficiency: ELCO AEROTOP SPK10 53, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 46; Noise: ELCO AEROTOP SPK10 75, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 64; Refrigerant: ELCO AEROTOP SPK10 44, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 45; Connectivity & smart: ELCO AEROTOP SPK10 50, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 50

Biggest differences

FactAEROTOP SPK10Vitocal 200-S AWB-M-E-AC 201.E08
Refrigerant GWP3675
Refrigerant charge3.4 kg1.5 kg
Heating capacity (A7/W35)4.1 kW6.83 kW
Indoor unit sound power32 dB(A)41 dB(A)
COP A7/W355.544.99
Min. outdoor temperature-22 °C-20 °C
All specifications ↓

Score per area = position (0–100) relative to all 1350 models in this category; higher is better.

Technical specificationsELCOAEROTOP SPK10ViessmannVitocal 200-S AWB-M-E-AC 201.E08
General
Type (source)Air-to-water1Air-to-water1
Performance
Heating capacity (A7/W35)4.1 kW26.83 kW✓3
Rated output 35 °C7.58 kW17.8 kW✓1
Rated output 55 °C7.4 kW✓17 kW1
Min. outdoor temperature-22 °C✓2-20 °C3
Efficiency
SCOP (35 °C)4.8614.9✓1
SCOP (55 °C)3.6✓13.331
Seasonal efficiency ηs 35 °C191 %1193 %✓1
Seasonal efficiency ηs 55 °C141 %✓1130 %1
Energy label 35 °CA+++2A+++3
Energy label 55 °CA++2A++3
COP A7/W355.54✓14.991
COP A2/W354.6514.79✓1
COP A-7/W352.8813.05✓1
Noise
Outdoor unit sound power53 dB(A)150 dB(A)✓1
Indoor unit sound power32 dB(A)✓141 dB(A)1
Refrigerant
RefrigerantR2901R321
Refrigerant GWP3✓26753
Refrigerant charge3.4 kg11.5 kg✓1
Electrical
Max. power input5.75 kW11.36 kW1
Connectivity & smart
SG ReadyYes1Yes1

Frequently asked questions

Which is better: the ELCO AEROTOP SPK10 or the Viessmann Vitocal 200-S AWB-M-E-AC 201.E08?

SCOP (35 °C): ELCO AEROTOP SPK10 4.86, Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 4.9. The Viessmann Vitocal 200-S AWB-M-E-AC 201.E08 is better on 8 of 16 comparable points.

What is the SCOP (35 °C) of the ELCO AEROTOP SPK10 and the Viessmann Vitocal 200-S AWB-M-E-AC 201.E08?

ELCO AEROTOP SPK10: 4.86. Viessmann Vitocal 200-S AWB-M-E-AC 201.E08: 4.9.

Which is better on refrigerant GWP: the ELCO AEROTOP SPK10 or the Viessmann Vitocal 200-S AWB-M-E-AC 201.E08?

ELCO AEROTOP SPK10: 3. Viessmann Vitocal 200-S AWB-M-E-AC 201.E08: 675.

Which is better on refrigerant charge: the ELCO AEROTOP SPK10 or the Viessmann Vitocal 200-S AWB-M-E-AC 201.E08?

Viessmann Vitocal 200-S AWB-M-E-AC 201.E08: 1.5 kg. ELCO AEROTOP SPK10: 3.4 kg.

How we collect and check this data →

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 29 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026