Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.16-400-V002 (Keymark 44099)

The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.16-400-V002 (Keymark 44099) is an air-to-water heat pump with a SCOP of 4.85 (35 °C) and a sound power level of 48 dB(A).1
Key figures
Rules in Malta
Water Heater Scheme (heat pump water heaters)
UnknownREWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).
Technical specifications
| General | |
|---|---|
| Type (source) | Air-to-water1 |
| System | Hybrid (with gas boiler)1 |
| Performance | |
| Heating capacity (A7/W35) | 8.5 kW1 |
| Rated output 35 °C | 13.29 kW1 |
| Rated output 55 °C | 12.09 kW1 |
| Min. outdoor temperature | -20 °C1 |
| Efficiency | |
| SCOP (35 °C) | 4.851 |
| SCOP (55 °C) | 3.921 |
| Seasonal efficiency ηs 35 °C | 190 %1 |
| Seasonal efficiency ηs 55 °C | 153 %1 |
| Energy label 35 °C | A+++1 |
| Energy label 55 °C | A+++1 |
| COP A7/W35 | 5.311 |
| Noise | |
| Outdoor unit sound power | 48 dB(A)1 |
| Indoor unit sound power | 40 dB(A)1 |
| Refrigerant | |
| Refrigerant | R2901 |
| Refrigerant GWP | 31 |
| Refrigerant charge | 2 kg1 |
How it ranks
SCOP (35 °C): better than 58% of comparable models in our database (Heat pumps · Air-to-water · 10–14 kW; n = 309).
Rank 125 of 310
Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.
Manufacturer documentation
- Datasheet / specifications — Datenblatt Vitocal 250-A Hybrid
- Brochure / leaflet — Prospekt Vitocal 250-A Hybrid
External links to Viessmann's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.
Similar models
Other brands, same type and a comparable size.
More from Viessmann
- Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.16-400-V002 SCOP (35 °C): 4.85
- Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.16-400-V002 SCOP (35 °C): 4.85
- Viessmann VITOCAL 300-G BWC 301.C16 SCOP (35 °C): 5.63
- Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.16-400-V001 SCOP (35 °C): 4.86
- Viessmann Vitocal 250-A IDU-A AWMIW.A1.19-V052 ODU 250-A AWMOF-251.A1.19-400-V001 SCOP (35 °C): 4.86
- Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.19-400-V002 SCOP (35 °C): 4.86
Featured in these lists
How we collect and check this data →
Frequently asked questions
Which refrigerant does the Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.16-400-V002 (Keymark 44099) use?
The Viessmann Vitocal 250-A IDU-A Hybrid HWMIW.A1.19-V054 ODU 250-A AWMOF-251.A1.16-400-V002 (Keymark 44099) uses R290.1
Sources
- Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
- Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)