Heat pumps · MT

Thermia iTec E 16 400V

Thermia iTec E 16 400V
Image: Thermiarequest removal

The Thermia iTec E 16 400V is an air-to-water heat pump with a SCOP of 4.48 (35 °C) and a sound power level of 66 dB(A).1,2

Key figures

SCOP (35 °C)
4.481

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
16kW2
Official source
Outdoor unit sound power
66dB(A)1
Official source
Refrigerant
R321
Official source
Type (source)
Air-to-water1
Official source
MT

Rules in Malta

Water Heater Scheme (heat pump water heaters)

Unknown

REWS runs a national grant scheme for energy-efficient water heaters in homes; heat pump water heaters are eligible (alongside solar water heaters). The scheme has been extended to 31 December 2026, and part A of the application must be submitted before you buy and install the equipment. Grant amounts: see the REWS page (not verified by us).

Technical specifications

General
Type (source)Air-to-water1
Compressors11
Capacity controldrehzahlregelung1
Performance
Heating capacity (A7/W35)16 kW2
Rated output 35 °C16 kW1
Rated output 55 °C16 kW1
Efficiency
SCOP (35 °C)4.481
SCOP (55 °C)3.531
Seasonal efficiency ηs 35 °C176 %1
Seasonal efficiency ηs 55 °C138 %1
Energy label 35 °CA+++2
Energy label 55 °CA++2
COP A7/W354.421
COP A2/W353.631
COP A-7/W352.611
Noise
Outdoor unit sound power66 dB(A)1
Indoor unit sound power40 dB(A)1
Refrigerant
RefrigerantR321
Refrigerant GWP6752
Refrigerant charge2.2 kg1
Electrical
Max. power input5.18 kW1
Connectivity & smart
SG ReadyYes1

How it ranks

SCOP (35 °C): better than 17% of comparable models in our database (Heat pumps · Air-to-water · ≥ 14 kW; n = 219).

Rank 179 of 220

Compared with every model on VersusIndex in the same group with a known value; equal values do not count as better. This says nothing about price, installation or reliability.

Manufacturer documentation

External links to Thermia's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Similar models

Other brands, same type and a comparable size.

More from Thermia

All Thermia models (16) →

How we collect and check this data →

Frequently asked questions

Which refrigerant does the Thermia iTec E 16 400V use?

The Thermia iTec E 16 400V uses R32.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026
  3. Water Heater Scheme (heat pump water heaters) — Regulator for Energy and Water Services (REWS)