Heat pumps · MT

TecalorTTL 9.6 AC

Tecalor TTL 9.6 AC
Image: Tecalorrequest removal

The Tecalor TTL 9.6 AC is an air-to-water heat pump with a SCOP of 4.31 (35 °C) and a sound power level of 55 dB(A).1,2

Last updated: Technical specifications ⇄ Compare this model

Key figures

SCOP (35 °C)
4.311

Seasonal efficiency: how much heat you get per kWh of electricity across a heating season.

Heating capacity (A7/W35)
8.24kW2
Official source
Outdoor unit sound power
55dB(A)1
Official source
Refrigerant
R452B1
Official source
Type (source)
Air-to-water1
Official source

Technical specifications

General
Type (source) Air-to-water1
Compressors 11
Capacity control drehzahlregelung1
Performance
Heating capacity (A7/W35) 8.24 kW2
Rated output 35 °C 11.2 kW1
Rated output 55 °C 11.6 kW1
Efficiency
SCOP (35 °C) 4.311
SCOP (55 °C) 3.451
Seasonal efficiency ηs 35 °C 169 %1
Seasonal efficiency ηs 55 °C 135 %1
Energy label 35 °C A, , 2
Energy label 55 °C A, , 2
COP A7/W35 4.611
COP A2/W35 3.821
COP A-7/W35 3.361
Noise
Outdoor unit sound power 55 dB(A)1
Refrigerant
Refrigerant R452B1
Refrigerant GWP 6982
Refrigerant charge 5 kg1
Electrical
Max. power input 5.5 kW1
Connectivity & smart
SG Ready Yes1

Manufacturer documentation

External links to Tecalor's official website. The manufacturer may change or move documents; where they differ, the manufacturer's latest version applies.

Compare with

Frequently asked questions

Which refrigerant does the Tecalor TTL 9.6 AC use?

The Tecalor TTL 9.6 AC uses R452B.1,2

Sources

  1. List of eligible heat pumps (BEG) — Bundesamt für Wirtschaft und Ausfuhrkontrolle (BAFA) · accessed 27 Sept 2026
  2. Heat Pump Keymark certificates — EHPA / DIN CERTCO (Heat Pump KEYMARK) · accessed 29 Sept 2026